Installation Instructions | 2.0 

Installation 

 

Bosch Security Systems, Inc. | 7/05 | 4998138530F 

 

Back-to-Back Pole Mounting 

 

Figure 8: 

Back-to-Back Pole Mounting 

 

 

1.

 

With spacers between the two units, mount the 
transmitter and the receiver back-to-back. Refer to 

Figure 8

2.

 

Use nuts and bolts to attach each unit firmly to the 
pole. 

3.

 

Make sure that the units are aimed so that the 
transmitter and the receiver in the same set are 
aligned with each other. 

2.2.2 Wall 

Mounting 

Refer to 

Figure 9

 for Steps 1 through 7. 

1.

 

Loosen the transmitter’s cover mounting screw and 
remove the cover. 

2.

 

Loosen the two base mounting screws and remove 
the chassis by sliding it down against the base. 

3.

 

Insert wiring through the chassis wire entrance, 
leaving enough wire to access the transmitter’s 
terminal block. 

4.

 

Insert the chassis mounting screws through the 
mounting holes to mount the chassis on the 
mounting surface. 

5.

 

Insert wiring through the wire entrance of the 
transmitter. Remove the wire entrance at the 
bottom of the transmitter. 

6.

 

Reattach the transmitter to the chassis. 

7.

 

Repeat this mounting procedure for the receiver. 
Make sure it is mounted in a direct line-of-sight to 
the transmitter. 

 

Figure 9: 

Wall Mounting 

1

2

3

7

4

5

6

8

 

1 -  Chassis  

2 -  Base 

3 -  Cover 

4 -  Mounting holes 

5 -  Terminal block 

6 -  Wire entrance 

7 -  Base mounting screws 

8 -  Cover mounting screw

 

Summary of Contents for DS484Q

Page 1: ...EN Installation Instructions Quad Beam Photoelectric Detectors DS484Q DS486Q ...

Page 2: ...eased system flexibility by allowing multiple devices to be used near each other without cross talk or other interference 1 2 Components Figure 1 DS484Q DS486Q Components 1 2 3 12 17 11 10 6 7 8 5 13 14 15 16 9 4 1 Chassis 2 Base 3 Cover 4 Mounting holes 5 Vertical adjustment screw upper 6 Terminal block transmitter has five terminals receiver has nine terminals 7 Wire entrance 8 Vertical adjustme...

Page 3: ... Allowance Stable operation is maintained even if 99 of beam energy is cut by environmental disturbances such as rain fog or frost 1 3 2 Beam Power Control Use this feature to select the appropriate beam intensity for the detection range Controlling beam intensity minimizes the risk of reflection off nearby walls and cross detection with other detectors 1 3 3 Beam Interruption Time Control Use thi...

Page 4: ... in the ON position To use the EDC Bypass Switch set the receiver s DIP Switch 5 to ON or OFF Figure 4 Refer to Table 1 for information about the functions and detector status Connect the EDC to a trouble circuit Check the system after the EDC relay activates Table 1 EDC BYPASS Switch States Detector Status BYPASS Switch OFF BYPASS Switch ON EDC LED lights and EDC signal is provided through the no...

Page 5: ...all or wire detectors during a thunderstorm Do not supply power until all wiring is completed Maintain power between 10 5 VDC and 28 VDC at all times Do not disassemble or modify the base 2 1 1 Beam Strength over Distance The beam strength is best if used within the maximum range of the detectors If used for shorter distances excess beam energy reaches the receiver resulting in reflection off near...

Page 6: ...d 4 cm 1 5 in and 1 6 in use the shorter flange 1 0 cm 0 4 in of the mounting plate If the pole diameter is between 4 cm 1 6 in and 4 3 cm 1 7 in use the longer flange 1 5 cm 0 6 in of the mounting plate This ensures that the end of the screw does not contact the pole Figure 6 Using Mounting Plates 1 3 2 1 Mounting plate 2 Chassis 3 Short clamping screws 3 Use the U clamps and the long clamping sc...

Page 7: ...ove the cover 2 Loosen the two base mounting screws and remove the chassis by sliding it down against the base 3 Insert wiring through the chassis wire entrance leaving enough wire to access the transmitter s terminal block 4 Insert the chassis mounting screws through the mounting holes to mount the chassis on the mounting surface 5 Insert wiring through the wire entrance of the transmitter Remove...

Page 8: ...ol panel capable of providing standby power for at least 4 hours Test this system at least once a week to ensure proper operation Table 3 Wire Length AWG Chart Maximum Distance m ft DS484Q DS486Q Wire Gauge mm 2 AWG 12 VDC 24VDC 12VDC 24VDC 0 8 22 90 295 850 2789 80 295 730 2395 1 06 19 180 591 1670 5479 150 492 1420 4659 1 37 17 330 1083 3020 9908 280 919 2580 8465 1 8 14 590 1936 5370 17618 500 ...

Page 9: ... Set Wiring Example 1 3 2 4 5 COM NC 1 Terminal block on transmitter and receiver 2 Receiver 3 Transmitter 4 Power output 5 Alarm input INC Figure 13 Two Sets on the Run Wiring Example 1 3 2 4 5 2 3 COM NC COM NC 1 Terminal block on transmitter and receiver 2 Receiver 3 Transmitter 4 Power output 5 Alarm input INC ...

Page 10: ...t EDC on page 4 for more information The EDC is always on DIP Switch 5 BYPASS controls the alarm condition relative to the EDC relay status Refer to Figure 4 on page 4 If DIP Switch 5 is ON the system alarms only if the EDC relay is not activated If the EDC is activated the system does not indicate an alarm If DIP Switch 5 is OFF the system alarms regardless of whether the EDC relay is activated o...

Page 11: ...etting Range m ft Volume Setting Range m ft 80 0 to 80 0 to 263 120 0 to 120 0 to 394 120 40 to 120 263 to 394 200 120 to 200 394 to 656 160 120 to 160 394 to 525 260 200 to 260 656 to 853 200 160 to 200 525 to 656 320 260 to 320 853 to 1050 220 200 to 220 656 to 722 360 320 to 360 1050 to 1181 240 220 to 240 722 to 787 400 360 to 400 1181 to 1312 4 1 3 Beam Group and Channel Setup When installing...

Page 12: ...ch 2 3 Channel OFF OFF M OFF ON 1 ON OFF 2 ON ON 3 One transmitter and one receiver facing each other are a set In a set each unit must have the same setting for group and for channel When installing two or more sets use different settings for each set transmitter and receiver to avoid incorrect communication 4 1 4 Synchronized Wiring Synchronized abbreviated synchro wires are required when instal...

Page 13: ...lignment methods Voltmeter Level LED and Sound Alignment interruption sheets Figure 19 are used in all three procedures to cover all optical modules in the installation except the pair that are being aligned Select a procedure based on the conditions and considerations of the specific installation Refer to Table 9 Figure 19 Alignment Interruption Sheet Table 9 Fine Alignment Considerations Alignme...

Page 14: ...tical module 5 Use the turntable to adjust the horizontal angle of the optical module until the receiver image appears in the viewfinder Refer to Figure 21 and Figure 22 6 Use the horizontal and vertical adjustment screws to center the receiver image in the outline of the scope aperture Refer to Figure 21 and Figure 22 7 Repeat Steps 3 through 6 for the other optical module on the transmitter 8 Do...

Page 15: ...begin this procedure the LEDs are off 2 Use a screwdriver to adjust the optical modules Adjust the horizontal and vertical adjustment screws as necessary Refer to Figure 21 3 As more beam energy is received each LED turns on flashes quickly flashes slowly and then turns off 4 Continue fine tuning until the LEDs turn off If outdoors the alignment is complete when all LEDs are off If indoors the ali...

Page 16: ...pt time is set too low or the alignment is not correct Walk across the beam path in several locations between the detectors Figure 24 Each time you cross the beam path the ALARM LED should activate If not the beam interrupt time is set too low or the alignment is not correct Figure 24 Walk Test Pattern 4 1 2 3 1 Receiver 2 Transmitter 3 Beam path 4 Crossing the beam path Inspect the system and per...

Page 17: ...e 25 The correct DIP switch settings are shown for each transmitter and receiver Figure 25 Examples of Stacking Multiple Transmitter and Receiver Sets 2 3 1 2 4 5 M 1 2 3 1 1 1 Receiver 2 Transmitter 3 Synchronized wiring 4 Receiver DIP switches 5 Transmitter DIP switches Each top line set must be set to Channel M and the other line sets to Channels 1 2 or 3 to avoid incorrect communication betwee...

Page 18: ...rferency RFI nearby Change the installation site Wiring too close to power sources or power line Change the routing of the wiring Unstable installation site Fix the installation site Out of maximum protection range Reinstall the units within the maximum protection range Refer to Section 2 1 Installation Considerations on page 5 Inappropriate Beam Power Control level Readjust the control level Refe...

Page 19: ...e Indoor DS486Q 300 m 1000 ft Enclosure Design Material Polycarbonate Dimensions HxWxD 35 cm x 10 cm x 11 cm 13 75 in x 4 in x 4 1 in Receiver 1 2 kg 2 64 lb Total Weight Transmitter 1 2 kg 2 64 lb Environmental Considerations Operating Temperature 25 C to 55 C 13 F to 130 F IP Rating IP 54 protection against dust protection against splashing water Mounting Location Surface or pole mount Pattern P...

Page 20: ... 2005 Bosch Security Systems 4998138530F Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 ...

Reviews: