background image

To set up the detector

1. Mount the cover.
2. Insert the tamper screw, if desired.
3. Apply power to the unit.
4. Wait for approximately two minutes with no

motion in the monitoring area, then begin
walk testing across the pattern below.

5. Walk test the detector from both directions.

The boundaries are determined by activation
of the LED.

6. If the desired range is not achieved, angle

the mirror up or down to assure the monitor-
ing pattern is not aimed too high or too low.

7. If required, install the security seal (P/N

3.102.389.687) between the base and cover
beside the cover locking screw.

Monitoring Patterns

Wide-angle monitoring

Use wide-angle monitoring to overlap monit-
oring areas when using more than one de-
tector.

Vertical swivel range of the mirror: +2° to
-16°

A B C D E F G H I

J K L M N

O P Q

11

0

0

0

5.5

5.5

5.5

5.5

11

B

A

D

C

E

G

F

H

I

J

K

L

M

N

P

Q

O

0

Q

0

3

2

11

11

0

0

O-

J- N

A - I

Mirror segment to 
pattern reference

Top
view

Side
view
(-6°)

Curtain Monitoring

Use curtain monitoring by installing the
OMLR93-3 long-range mirror in the detector.

Vertical swivel range of the mirror: +7° to
-16°

A

B

C D E

0

1.5

2

21

1.5

0

21

0

0

3

0

21

21

0

0

0

1.5

1.5

A

E

D

C

B

Mirror segment to 
pattern reference

Top
view

Side
view
(-3°)

Maintenance

Check the range and monitoring area with a
walk test at least once a year.

Instruct the end user to check the detector
daily by walking through the outer edge of
the monitoring area and observing the LED
operation (if used). This assures an alarm
output prior to arming.

Technical data

Electrical

Maximum operating voltage in VDC

33

Maximum current consumption in mA 0.8

Mechanical

Dimension in cm (H x W x D)

11 x 6.9 x 4.5

Monitoring area in m

Wide-angle mirror

11 x 11

Curtain mirror

21 x 3

Minimum installation height in
m

2

Maximum installation height in
m

2.6

Rates of movement in m/s

Wide-angle mirror

0.2 - 3.0

Curtain mirror

0.2 - 4.0

Sensitivity setting

Standard or
high sensitivity

Environmental

Minimum operating temperature in °C -10

Maximum operating temperature in
°C

55

Minimum storage temperature in °C

-20

Maximum storage temperature in °C

60

Maximum relative humidity in %

95; no
dew
point

Protection class

IP41 /
IK02

Environmental class

II

9 |