Cleaning and care

Isolate the extractor hood by pulling out
the mains plug or switching off the fuse.

Do not clean the extractor hood with

abrasive sponges or with cleaning agents
which contain sand, soda, acid or chlorine!

Clean the extractor hood with a hot soap
solution or a mild window cleaner.

Do not scrape off dried-on dirt but wipe
off with a damp cloth.

When cleaning the grease filters, remove
grease deposits from accessible parts of
the housing. This prevents the risk of fire
and ensures that the extractor hood
continues operating at maximum 
efficiency.

Clean the operating buttons with a mild

soapy solution and a soft, damp cloth only.
Do not use stainless-steel cleaner to clean
the operating buttons.

Stainless steel surfaces:

Use a mild non-abrasive stainless steel
cleaner.

Clean the surface in the same direction
as it has been ground and polished.

We recommend our stainless steel 
cleaner no. 461731.
See enclosed service booklet for order
address.

Aluminium, coated and plastic surfaces:

Do not use dry cloths.

Use a mild window cleaning agent.

Do not use aggressive, acidic or caustic
cleaners.

Observe the warranty regulations in the
enclosed service booklet.

4.

Re-insert the bulb ring.

5.

Plug the appliance into the mains or
switch it on at the fuse box.

Note: I

f the light does not function, check

that the bulbs have been inserted correctly.

Replacing the light bulbs

1.

Switch off the extractor hood and pull
out the mains plug or switch off the
electricity supply at the fuse box.

When switched on, the halogen bulbs

become very hot. Even for some time after
the bulbs have been switched off there is
still a risk of burns.

2.

Remove the bulb ring with a screwdriver
or similar tool.

3.

Replace the halogen light bulb 
(conventional halogen bulb, 12 Volt,
max. 20 Watt, G4 cap).

Caution:

Refer for plug-in lampholder.

Take hold of the bulb with a clean cloth.

Summary of Contents for DKE 985 C

Page 1: ...Operating and installation instructions DKE 985 C Internet http www bosch hausgeraete de Bosch Info Team de Tel 01 80 5 30 40 50 E 0 14 Min DTAG ...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ ...

Page 3: ...cking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the ...

Page 4: ...taneously Before using your appliance for the first time please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care of the appliance Please retain the operating and installation instructions for a subsequent owner Do not use the appliance if damaged The appliance is not intended for use by young children or infirme...

Page 5: ...tching off Repeat the process with the light switched on After approx 3 seconds the light switches off to acknowledge the setting Light Fan OFF Reduce fan speed Fan ON and increase speed Display for fan setting Fan follow on Operating procedure Acoustic signal When a button is pressed this is verified by an acoustic signal Switching off the acoustic signal Simultaneously press buttons 0 and until ...

Page 6: ...itched off and an appears in the display The grease filters should be cleaned straight away Cleaning the metal grease filters The filters can be cleaned in a dishwasher It is however possible that they will become slightly discoloured Important Metal filters that are saturated with grease should not be washed together with other dishes etc When cleaning the filters by hand soak them in hot soapy w...

Page 7: ...activated carbon filters They can therefore be disposed of as part of your normal domestic refuse Filters and maintenance 3 Engage the catches at both sides 4 Insert the metal grease filters see Removing and inserting the metal grease filters 5 Cancel the ã in the display Press the 0 button Activated carbon filter For neutralizing odours in recirculating mode Caution As the filter becomes more and...

Page 8: ...n as it has been ground and polished We recommend our stainless steel cleaner no 461731 See enclosed service booklet for order address Aluminium coated and plastic surfaces Do not use dry cloths Use a mild window cleaning agent Do not use aggressive acidic or caustic cleaners Observe the warranty regulations in the enclosed service booklet 4 Re insert the bulb ring 5 Plug the appliance into the ma...

Page 9: ...er Service representatives When you call please quote the following Setting the saturation indicator If it becomes necessary to change the operating mode exhaust air recirculating mode the saturation indicator for the filters must also be altered see Installation Instructions E Nr FD Enter the relevant numbers into the box above The E Nr product no and FD production date are shown on the nameplate...

Page 10: ...ials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can be used in exhaust air or circulating air mode The applicable regulations of the power supply company and compliance of lo...

Page 11: ...mbustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk o...

Page 12: ... cross section that equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adequate supply of fresh air Circulating air mode With activated carbon filter if exhaust air mode is not possible The complete installation set can be obtained from spec...

Page 13: ...low Earth wire to the terminal in the plug marked E or with the symbol or coloured green or green and yellow 2 Connect the blue Neutral wire to the terminal in the plug marked N or coloured black 3 Connect the brown Live wire to the terminal marked L or coloured red The extractor hood should only be con nected to an earthed socket that has been installed according to relevant regulations If possib...

Page 14: ... hood at the centre of the location where the hood is going to be mounted 3 Use the template to mark the points on the wall where the screws will be moun ted In order to make it easier to hook the hood onto the screws draw the out line of the area where the hood will be attached Ensure that the minimum distance between the hob and the extractor hood is maintained 550 mm for an electric hob and 650...

Page 15: ... for example by laying the template used for marking the wall over the top edge of the lower section 10 Connect up the air outlet pipe 11 Connect the hood to the electricity supply 12 Remove the protective film from the two flue ducts Take care not to damage the stainless steel surfaces which are susceptible to scratches etc Warning The interior walls of the flue panelling can have sharp edges Ris...

Page 16: ...9000 235 989 Printed in Germany 0407 Es Robert Bosch Hausgeräte GmbH DHZ 5165 1 2 3 4 5 6 2x 10x 2x 351210 ...

Reviews: