Prior to installation

Exhaust air

Recircula-

ting air

20,2

60 cm

22,4

21,5

23,7

70 cm

23,2

25,4

90 cm

We reserve the right to construction changes within the 
context of technical development.

Preparing the wall

The wall must be flat and perpendicular.

Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.

Weight in kg:

Changing over from exhaust-
air to recirculating mode

Changing the electronic control system
to recirculating mode:

The standard factory setting is for
operation in exhaust-air mode.

To change the mode, the extractor hood
must have been connected up and
should be switched off.

1.

Press and hold the 

0

button.

2.

While 

{

is displayed, press the 

button until 

ã

is displayed. When this

has taken place, release the buttons.

ã

goes out shortly afterwards.

The electronic control system will then
have been set to recirculating mode.

By repeating steps 

1

and 

2, 

you can

change the electronic control system
back to exhaust-air mode (

#

in display).

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:

The wires in the mains lead are coloured in
accordance with the following code:

Green and Yellow

– Earth

Blue

– Neutral

Brown

– Live

Electrical connection

If you fit your own plug, the colours of 
these wires may not correspond with the
identifying marks on the plug terminals.
This is what you have to do:

1.

Connect the green and yellow (Earth) 

wire to the terminal in the plug marked
‘E’ or with the symbol (        ), or 
coloured green or green and yellow.

2.

Connect the blue (Neutral) wire to the 

terminal in the plug marked ‘N’ or 
coloured black.

3.

Connect the brown (Live) wire to the 

terminal marked ‘L’, or coloured red.

The extractor hood 

should only be con-

nected to an earthed socket that has been
installed according to relevant regulations.
If possible, site the earthed socket directly
behind the chimney panelling.

The earthed socket should be 
connected via its own circuit.

If the earthed socket is no longer 
accessible following installation of the
extractor hood, ensure that there is a
permanently installed disconnector.

If it is necessary to wire the extractor
hood directly into the mains:

The extractor hood should only be
connected to the electricity supply by a 
properly qualified electrician.
A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such devices
include circuit breakers and contactors.

If the connecting cable for this 

appliance is damaged, the cable must be
replaced by the manufacturer or his custo-
mer service or a similarly qualified person in
order to prevent serious injury to the user.

Electrical data:

Are to be found on the name plate inside
the appliance after removal of the filter
frame.

Before undertaking any repairs,

always disconnect the extractor hood from
the electricity supply.

Length of the connecting cable: 1.30 m.

This extractor hood corresponds to EC
regulations concerning RF interference 
suppression.

13

Summary of Contents for DKE 985 C

Page 1: ...Operating and installation instructions DKE 985 C Internet http www bosch hausgeraete de Bosch Info Team de Tel 01 80 5 30 40 50 E 0 14 Min DTAG ...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ ...

Page 3: ...cking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the ...

Page 4: ...taneously Before using your appliance for the first time please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care of the appliance Please retain the operating and installation instructions for a subsequent owner Do not use the appliance if damaged The appliance is not intended for use by young children or infirme...

Page 5: ...tching off Repeat the process with the light switched on After approx 3 seconds the light switches off to acknowledge the setting Light Fan OFF Reduce fan speed Fan ON and increase speed Display for fan setting Fan follow on Operating procedure Acoustic signal When a button is pressed this is verified by an acoustic signal Switching off the acoustic signal Simultaneously press buttons 0 and until ...

Page 6: ...itched off and an appears in the display The grease filters should be cleaned straight away Cleaning the metal grease filters The filters can be cleaned in a dishwasher It is however possible that they will become slightly discoloured Important Metal filters that are saturated with grease should not be washed together with other dishes etc When cleaning the filters by hand soak them in hot soapy w...

Page 7: ...activated carbon filters They can therefore be disposed of as part of your normal domestic refuse Filters and maintenance 3 Engage the catches at both sides 4 Insert the metal grease filters see Removing and inserting the metal grease filters 5 Cancel the ã in the display Press the 0 button Activated carbon filter For neutralizing odours in recirculating mode Caution As the filter becomes more and...

Page 8: ...n as it has been ground and polished We recommend our stainless steel cleaner no 461731 See enclosed service booklet for order address Aluminium coated and plastic surfaces Do not use dry cloths Use a mild window cleaning agent Do not use aggressive acidic or caustic cleaners Observe the warranty regulations in the enclosed service booklet 4 Re insert the bulb ring 5 Plug the appliance into the ma...

Page 9: ...er Service representatives When you call please quote the following Setting the saturation indicator If it becomes necessary to change the operating mode exhaust air recirculating mode the saturation indicator for the filters must also be altered see Installation Instructions E Nr FD Enter the relevant numbers into the box above The E Nr product no and FD production date are shown on the nameplate...

Page 10: ...ials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can be used in exhaust air or circulating air mode The applicable regulations of the power supply company and compliance of lo...

Page 11: ...mbustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk o...

Page 12: ... cross section that equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adequate supply of fresh air Circulating air mode With activated carbon filter if exhaust air mode is not possible The complete installation set can be obtained from spec...

Page 13: ...low Earth wire to the terminal in the plug marked E or with the symbol or coloured green or green and yellow 2 Connect the blue Neutral wire to the terminal in the plug marked N or coloured black 3 Connect the brown Live wire to the terminal marked L or coloured red The extractor hood should only be con nected to an earthed socket that has been installed according to relevant regulations If possib...

Page 14: ... hood at the centre of the location where the hood is going to be mounted 3 Use the template to mark the points on the wall where the screws will be moun ted In order to make it easier to hook the hood onto the screws draw the out line of the area where the hood will be attached Ensure that the minimum distance between the hob and the extractor hood is maintained 550 mm for an electric hob and 650...

Page 15: ... for example by laying the template used for marking the wall over the top edge of the lower section 10 Connect up the air outlet pipe 11 Connect the hood to the electricity supply 12 Remove the protective film from the two flue ducts Take care not to damage the stainless steel surfaces which are susceptible to scratches etc Warning The interior walls of the flue panelling can have sharp edges Ris...

Page 16: ...9000 235 989 Printed in Germany 0407 Es Robert Bosch Hausgeräte GmbH DHZ 5165 1 2 3 4 5 6 2x 10x 2x 351210 ...

Reviews: