18
en
Activated carbon fi lter:
For neutralizing odours in recirculating mode.
Caution:
As the fi lter becomes more and more saturated with
grease, there is an increased risk of fi re and the
function of the hood may be impaired.
Important:
Change the activated carbon fi lter promptly to pre-
vent the risk of fi re from the accumulation of heat
when deep-fat frying or roasting.
These fi lters are not washable and cannot be regen-
erated, and must be replaced when the C-sign ap-
pears on the display or approximately every year of
operation, or more frequently with heavy usage.
Activation of the alarm signal
In the recycling version hoods the fi lter satura-
tion alarm must be activated during the installa-
tion or later.
Switch off the hood and the lights.
Disconnect the hood from the mains supply.
When restoring the connection press and hold
B-key.
When releasing the key two rotating rectangles
appear on the display.
Within 3 seconds press the B-key until a fl ash-
ing confi rmation appears on the dispaly:
2 fl ashes with C-sign - charcoal fi lter satu-
ration alarm ACTIVATED
1 fl ash with C-sign - charcoal fi lter satura-
tion alarm DEACTIVATED.
Replacing the activated carbon fi lter
Reset of the alarm signal
Switch off the hood and the lighting.
Press
the
E-key until the display is unlit.
Replacing of the fi lter
Open the ducting panels pulling them down-
wards.
Remove the metal grease fi lters.
Filters and maintenance
Remove the saturated charcoal fi lter by releas-
ing the fi xing hooks.
Filters and maintenance
Fit the new fi lter and fasten it in its correct
position. Filter can be ordered at the customer
service
Put the metal grease fi lters in their seats.
Close the comfort panels.
Disposal of the old activated carbon fi lter:
Activated carbon fi lters do not contain any
harmful substances. They can be disposed of
as residual waste.