DIVAR IP 6000 (3U)
Rack installation | en
23
Bosch Sicherheitssysteme GmbH
Installation Manual
2016.08 | V2.1 | DOC
To install the chassis in the rack:
1.
Align the inner rails of the chassis with the outer rails on the rack.
2.
Slide the inner rails into the outer rails, keeping the pressure even on both sides. When
the chassis has been pushed completely into the rack, it should click into the locked
position.
3.
Optionally, screws may be used to hold the front of the chassis to the rack.
4.3.6
Installing the chassis in a Telco rack
Notice!
Do not use a two post "Telco" type rack.
!
Warning!
Stability hazard
Before sliding the unit out for servicing make sure that the rack stabilizing mechanism is in
place, or the rack is bolted to the floor. Failure to stabilize the rack can cause the rack to tip
over.
!
Warning!
Do not pick up the unit with the front handles. The handles are designed to pull the system
from a rack only.
Notice!
Mounting the chassis into the rack requires at least two people to support the chassis during
installation. Please follow safety recommendations printed on the rails.
Notice!
Figures are for illustrative purposes only. Always install chassis into racks from the bottom
up.
To install the chassis into a Telco type rack, use two L-shaped brackets on either side of the
chassis (four in total). First, determine how far the chassis will extend out the front of the
rack. Larger chassis should be positioned to balance the weight between front and back. If a