1 689 989 283
2020-02-24
|
Robert Bosch GmbH
Technical Data | DCU 100 | 23 |
8. Technical Data
8.1
Temperature and humidity
Designation
Value / range
Operating Temperature
5 °C – 40 °C
41 °F – 104 °F
Storage Temperature
-20 °C – 60 °C
-4 °F – 140 °F
Relative operating humidity
20 – 80 % non-
condensing
8.2
DCU 100
Property
Value / range
Display
10“ TFT, WXGA
(1024 x 600 Pixel)
Operating system
Windows 10 IoT (64-bit)
Interfaces
USB 3.0 (2x)
LAN 10/100 Mbit
VGA, Audio
Main-memory capacity
4 GB DDR3 RAM
Hard disk
256 GB SSD
WLAN
WLAN 802.11 b/g/n
Bluetooth
Bluetooth 2.1
Class 1
Power supply unit
12 V
Storage battery (Li-ion)
7,26 V/ 5200 mAh
Dimensions (H x W x D)
222 x 361 x 53 mm
8.7 x 14.2 x 2.1 inch
Weight with storage battery,
without power supply unit
2,1 kg
4.6 lb
Degree of protection
IP 20
8.3
Bluetooth Class 1
Wireless link
Minimum range
Free field workshop environment
30 m
In passenger compartment, with ve-
hicle door or window open and en-
gine running
10 m
8.4
RED (Radio Equipment Directive)
Wireless link
Frequency band
Maximum radiated
transmitter power
output
Bluetooth
2,4 GHz
19,9 dBm
WLAN
2,4 GHz
19,9 dBm
8.5
Power supply unit
Property
Value / range
Input voltage (AC)
100 - 240 VAC
Frequency
50 – 60 Hz
Input current
1,6 A
Output voltage (DC)
12 V
Max. output current
5.0 A
de
Summary of Contents for DCU 100