background image

Notice:

Remove this page before giving this manual to

the system owner.

How to Customize this Manual for the System Owner

Be sure to check the appropriate boxes on pages describing system
commands so that the end user will know (a) whether a function is
available and (b) whether a passcode is required for the function.

Functions Not Available with the D7112

The following functions are not available for the D7112:

COMMAND 53 Delete Passcodes

COMMAND 58 Fire Test

COMMAND 8 Perimeter Partial

COMMAND 00 Unbypass Point

Be sure to check the “I do not have this feature” box for each of
these commands when the D720 is to be used with the D7112.

Summary of Contents for D720

Page 1: ...LED Command Center U s e r s G u i d e ...

Page 2: ...sted unless the family has planned for a quick evacuation Because there may be very little time between detection of a fire and the time it becomes deadly it is important that every member of the family understand exactly what to do Possible escape routes through open windows marked with arrows Primary and alternate escape routes should be established Since stairwells and hallways may be blocked d...

Page 3: ...ming stations or detectors yourself Call _________________________________________ Before Testing The security system is connected to this telephone number __________________________________________________________ The security control panel is connected to the phone jack located __________________________________________________________ AC Power Failure If your command center indicates that AC po...

Page 4: ...nce door or an area of your property like the second floor Each point is represented by its point number on the Command Center display panel There are two basic types of points controlled and 24 hour Controlled Points Controlled points respond to alarm conditions depending upon whether the system is turned on armed or turned off disarmed Controlled points are programmed to respond instantly to ala...

Page 5: ... If the point status indicators are not lit the system can be armed by entering your personal passcode or any of the arming com mands available to your system If any of the point status indicators are lit the system has a faulted point Correcting the faulted point will usually mean closing a door or window Power Indicator When the red PWR indicator LED lights steadily your security system is opera...

Page 6: ...System When entering a passcode or command at the Command Center each key must be pressed within five seconds of the last key entry After five seconds have expired from the last key entry the entire entry is cleared and the passcode must be started over Function Keys The Command Center has three function keys labeled A B and C The function keys can be used to perform system commands with the touch...

Page 7: ...s guide Turning the System Off Disarming Your security system is turned off by entering your personal passcode and pressing ENT When your system is turned on you must enter the premises through a designated entry door to prevent an immediate instant alarm condition Opening the door starts an entry delay time and the Command Center emits a pulsing beep tone to remind you to turn the system off Ente...

Page 8: ...y be programmed to send a closing report to your security company when arming My system sends a closing report My system does not send a closing report Your system may be programmed to send an opening report to your security company when disarming My system sends an opening report My system does not send an opening report Your system may be programmed to report Force Arming to your security compan...

Page 9: ...llowed by ENT 4 Entry Delay Tone When you enter the premises through a point programmed for entry delay the command center emits a repeating tweedle tone to remind you to turn off your system Exit Delay Tone After you arm your system the command center emits a repeating beep tone and counts down the exit delay time If you don t exit before the delay time expires and an exit delay door is faulted e...

Page 10: ...ess ENT It your system reports to a Central Station you need to call them if an alarm occurs Application COMMAND 1 is useful in applications where you want your cleaning service a service person or anyone else to arm your system when they leave but you do not want them to have the passcode to disarm the system COMMAND 1 arms the system but it will not disarm the system COMMAND 1 Arming with COMMAN...

Page 11: ...1 Using Command 11 1 Ensure that all points are secure All of the Point Status indicator lights on the Command Center should be off If they re not see the section describing Force Arming the System 2 Press the COMMAND bar The Command Mode indicator light comes on 3 Press the 1 key Now press the 1 key again 4 The PERIMETER INSTANT and INTERIOR lights come on This indicates that the perimeter instan...

Page 12: ...nd ready to retire for the evening In commercial installations this arming command is useful when you are working late and you want the perimeter of the building armed until you are ready to leave COMMAND 2 Arming with COMMAND 2 1 Ensure that all perimeter points are secure Interior points are not armed with this command and may remain faulted while arming with COMMAND 2 Perimeter point status lig...

Page 13: ...the house In commercial installations use this command to rearm your system when you are on the premises but not yet open for business COMMAND 3 Arming with COMMAND 3 1 Ensure that all perimeter points are secure Interior points are not armed with this command and may remain faulted while arming with COMMAND 3 Perimeter point status lights should be off If they re not see the section describing Fo...

Page 14: ...ystem trouble events COMMAND 4 To use COMMAND 4 1 Press the COMMAND bar The Command Mode indicator light comes on 2 Press the 4 key The Command Center trouble sounder is silenced and any flashing Point Status indicator lights are turned off if the point is normal If the point is not normal its indicator light will stay on solidly indicating the need for attention ...

Page 15: ...e is a status report Command 42 This status report sends the current condition of your system in addition to testing the communication link to your security company COMMAND 4 1 4 2 To use COMMAND 4 1 or COMMAND 4 2 1 Always call your security company before sending a test report 2 Ensure that your security system is disarmed 3 Press the COMMAND bar The Command Mode indicator light comes on 4 Press...

Page 16: ...unction 2 Call your security company using this phone number _________________________________________________________ This number is designated for the Remote Account Manager You must make the call using the telephone located _________________________________________________________ 3 Identify yourself and your premises account number name address etc and advise the operator of the programming ch...

Page 17: ...tection devices simply activate sensors and open protected doors and windows one at a time As each detection device is faulted the Command Center emits a brief tone and the display indicates that the point has been tested This verifies that each detection device is working properly COMMAND 4 4 To use Walk Test 1 Ensure that your security system is idle 2 Press the COMMAND bar The Command Mode indi...

Page 18: ...t your security system is disarmed 2 Press the COMMAND bar The Command Mode indicator light comes on 3 Press the 4 key and then press the 7 key The display flickers momentarily and the command center emits multiple pips during reset If you enter this function and the detector or sensor resets momentarily but then returns to a faulted condition the conditions causing the activation may still be pre...

Page 19: ...scode you want to delete The two digit user numbers identify users in reports transmitted from your system COMMAND 5 3 To delete passcodes 1 Ensure that your security system is idle 2 Press the COMMAND bar The Command Mode indicator light comes on 3 Press the 5 key and then press the 3 key Your security system is now in the passcode delete mode 4 Enter the two digit user number for the passcode yo...

Page 20: ...ting with other passcodes and duress codes your system does not let you change to passcodes that are within plus or minus 2 of an existing passcode For example if 1234 were an existing code your system would not let you change your code to 1232 1233 1235 or 1236 COMMAND 5 5 To change your personal passcode 1 Ensure that your security system is idle 2 Press the COMMAND bar The Command Mode indicato...

Page 21: ...nel restores A message will be sent to your security company upon initiation and completion of the fire test During the fire test no 24 hour alarms will be sent to your security company If there is no activity on the system for 20 minutes the system will automatically exit from the fire test COMMAND 5 8 To use Fire Test 1 Ensure that your security system is idle 2 Press the COMMAND bar The Command...

Page 22: ...lly turns the Watch Mode on whenever you disarm Application This command is useful in a residential system when you want to monitor entrances or exits in your home In commercial installations the Watch Mode can be used as a door chime to alert you when a customer or delivery person has entered your business COMMAND 6 To use COMMAND 6 1 Ensure that your security system is idle 2 Press the COMMAND b...

Page 23: ...larm signal on the premises Check with your security company for the options they offer COMMAND 7 To engage COMMAND 7 1 Press the COMMAND bar The Command Mode indicator light comes on 2 Press the 7 key Your COMMAND 7 special alert has been pro grammed to _____ notify your alarm company _____ ring a bell on your premises Description __________________________________________________________ _______...

Page 24: ...eed access to the large overhead doors to receive deliveries using this function will allow you to keep the rest of the building perimeter armed COMMAND 8 To arm with COMMAND 8 1 Ensure that the command center is disarmed 2 Decide which points are to be left disarmed Fault the points doors and windows by leaving them open The point s must remain open until after the exit delay time expires 2 Press...

Page 25: ...larm signal on the premises Check with your security company for the options they offer COMMAND 9 To engage COMMAND 9 1 Press the COMMAND bar The Command Mode indicator light comes on 2 Press the 9 key Your COMMAND 9 special alert has been pro grammed to _____ notify your alarm company _____ ring a bell on your premises Description __________________________________________________________ _______...

Page 26: ...oints remain bypassed until you unbypass them see Unbypassing a Point or some points may return when the area is disarmed COMMAND 0 To use Bypass aPoint 1 Ensure that your security system is disarmed 2 Press the COMMAND bar The Command Mode indicator light comes on 3 Press the 0 key The system is now in the Bypass mode Some points may be set by your alarm company so that they cannot be bypassed 4 ...

Page 27: ...ns COMMAND 0 0 To Unbypass a Point 1 Ensure that your security system is disarmed 2 Press the COMMAND bar The Command Mode indicator light comes on 3 Press the 0 key then press the 0 key again The system is now the Unbypass mode 4 To unbypass a point press the number key that corresponds to the number of the point that is flashing slowly and then the ENT key The point status light stops flashing i...

Page 28: ...ress passcode is used when someone threatens you and demands that you disarm or arm your security system By disarming or arming with a duress passcode your security company is alerted of an alarm situation Passcode 1 or 2 The duress passcode is based on your personal passcode By increasing the last digit by one or two the duress feature is activated Example If your personal passcode is 1234 the du...

Page 29: ...arming command COMMANDs 1 2 or 3 The Command Center emits a buzz tone indicating a point is faulted 2 Press the COMMAND bar and then the ENT key The system now arms all points which are normal Note If the fault is restored returned to normal while arming the point will be armed If the fault is restored after arming how your system is programmed determines whether or not the point will be armed wit...

Page 30: ... door Once the delay door has been opened the entry delay begins If the security system is not disarmed before the delay time expires the system goes into alarm Exit Delay A predetermined amount of time provided by the security system to leave the armed building through a delay door Once the system is armed the exit time begins You must exit the building before the exit delay time expires Faulted ...

Page 31: ...rs will not detect intrusion Smoke detectors cannot detect smoke in chimneys walls or roofs or smoke blocked by a closed door They may not detect smoke or fire on a level of the building different from the one on which they are located Smoke detectors may not be able to warn in time about fires started by explosions improper storage of flammables overloaded electrical circuits or other types of ha...

Page 32: ...will know a whether a function is available and b whether a passcode is required for the function Functions Not Available with the D7112 The following functions are not available for the D7112 COMMAND 53 Delete Passcodes COMMAND 58 Fire Test COMMAND 8 Perimeter Partial COMMAND 00 Unbypass Point Be sure to check the I do not have this feature box for each of these commands when the D720 is to be us...

Page 33: ...71 06898 000 B 9 93 D720 ...

Page 34: ...User s Guides Menu Documents by Type Menu Documents by Product Menu Main Menu ...