D7024
| Operation and Installation Guide | 7.0 Control Panel Programming
40
Bosch | 7/05 | 31499J
The following window appears:
1.
Press [1] to program system to update bus.
2.
After programming Update Bus, the following
window appears:
Then the preceding window appears.
Setup Keypad
Shortcut:
0
-PROG >
3
-PROG SYSTEM >
4
-OPTION BUS
This feature tells the system how many keypads should
be supervised. It automatically performs an update bus
operation when it completes.
1.
Press [2] to set up keypads and access:
2.
Enter the desired value and press [#].
The current setting appears in parentheses on the
first line.
3.
After setting the keypads, the Update Bus operation
proceeds and the preceding window appears.
7.3.4
PIN REQUIRED
Local
Shortcut:
0
-PROG >
3
-PROG SYSTEM >
5
-PIN REQUIRED?
A PIN can be required before operations are performed
using the local, built-in keypad. The following window
appears:
1.
Press [1] to require a PIN at the local keypad and
access:
2.
Press the number key corresponding to your
selection.
The current setting appears in front of the colon on
the second line.
3.
After making your selection, the preceding window
appears.
Remote PIN
Shortcut:
0
-PROG >
3
-PROG SYSTEM >
5
-PIN REQUIRED?
The following window appears:
1.
Press [2] to select remote PIN and access:
2.
Press the number key corresponding to your
selection and then press [#].
The current setting appears in front of the colon on
the second line.
3.
Select the PIN to access the preceding window.
A PIN can be required before operations are performed
using the remote keypads on the option bus. If the
remote keypads are not secured, set this option to
YES
to comply with NFPA and UL requirements.
7.3.5
Remote Programming
Shortcut:
0
-PROG >
3
-PROG SYSTEM >
7
-REMOTE PGM
Remote programming allows you call the control panel
from a remote site by telephone to reconfigure any of
the programmable options. When remote programming
is disabled, you can still connect to the control panel for
diagnostics and to view the current program, except for
PINs that are suppressed while remote programming is
disabled.
1- UDPATE BUS
2- SETUP KEYPDS
OPTION BUS (M/M)
UPDATE COMPLETE
TOT BUS DEVS:X
1- UDPATE BUS
2- SETUP KEYPDS
OPTION BUS
# OF KEYPADS (_ _)
(0-4):_ _ _ _
1- LOCAL
2- REMOTE
PIN REQUIRED?
REMOTE KEYPD PIN?
_ _ _ _:YES(1)NO(2)
1- LOCAL
2- REMOTE
PIN REQUIRED?
REMOTE KEYPD PIN?
_ _ _ _:YES(1)NO(2)