D2212B/D2212BE Operation and Installation Guide
Page 34
© 2002 Bosch Security Systems
39934E
D2212B/D2212BE
Enclosures
The
D2203
enclosure is suitable for household fire and burglary applications only.
Enclosure tamper protection causing an immediate alarm signal is required for all burglary applications.
Bosch Security systems offers three optional enclosures:
The
D8103
enclosure is suitable for residential fire and/or burglary installations and commercial applications. See Table 7 on
page 37 for acceptable applications.
The
D8109
is normally used for fire alarm applications. The D8109 is approved by the Factory Mutual, California State Fire
Marshal, and the New York City Materials and Equipment Acceptance System.
The
D8108A
is attack resistant. It is intended primarily for UL commercial burglary and mercantile safe and vault
applications requiring a local bell. You can use the D8108A in an burglary application where the D8103 or D8109 enclosure is
suitable. The D8108A is approved by the Factory Mutual, California State Fire Marshal, and the New York City Materials
and Equipment Acceptance System.
The D2212 control panel is suitable for Police Station connect applications, including Grade A Mercantile Premises and Grade
A Mercantile Safe and Vault alarm systems. Suitable for Grade AA Mercantile Premises and Grade AA Mercantile Safe and
Vault alarm systems when the D2212 DACT unit is installed in conjunction with the D8122 Derived Channel Subscriber
Terminal Unit. For all Police Station applications and grades, the D8108A Attack Resistant Enclosure with a UL Listed local
sounding device is required. Per UL 365, keyswitches mounted outside the protected area must employ high security locking
cylinders complying with the requirements for key locks, UL 437. Tamper protection must also be provided.
The D2212 control panel is suitable for Local, Grade A Mercantile Premises and Local, Grade A Mercantile Safe and Vault
alarm systems. For all Local applications and grades, the D8108A Attack Resistant Enclosure and a UL Listed Local sounding
device are required. Per UL 609, when keyswitches are mounted outside the protected area, tamper protection must be
provided.
The D2212 control panel is suitable for Central Station, Grade C applications. It is suitable for Central Station, Grade B
applications when the D2212 DACT unit is installed with a UL Listed Local sounding device. Also suitable for Central Station
Mercantile, Grade AA applications when installed with the D8122 Derived Channel Subscriber Terminal Unit.
The D2212 control panel is suitable for Proprietary Burglar Alarm, Grade C applications. Also suitable for Proprietary
Burglar Alarm, Grade B applications when D2212 DACT unit is installed with a UL Listed Local sounding device. Also
suitable for Proprietary Burglar Alarm, Grade AA when the D2212 DACT unit is installed with a D8122 Derived Channel
Subscriber Terminal Unit.
The D2212 control panel is suitable for Household, Grade A applications.
UL Standard 681 for Installation and Classification of Mercantile and Bank Burglary Alarm systems requires foil lining of
equivalent protection of the control unit enclosure. The D8108A enclosure does not have foil lining, but acceptable protection
can be provided by mounting electronic vibration sensors inside the enclosure.
Proximity alarms (capacitance) cannot be used for this purpose.
Install electronic vibration sensors in the D8108A enclosure that are identical to those used to protect the safe or the vault.
Sentrol 5402, Potter EVD-S, or Arrowhead S-3810 electronic vibration detection (EVD) systems which can be mounted inside
the enclosure meet the requirements of UL 681. Mount the electronic vibration sensor directly inside the metal cabinet of the
D8108A.
Do not
install the sensor within 1/4 in. (6 mm) of the components or traces of the printed circuit assembly.
Appendix C