7.1.6
Easikey
You can use a Bosch Security Systems Easikey Access System to turn the system
Off
. Program the
Keyswitch
prompt to
Easikey. See the D2000 Series Program Entry Guide (P/N: 35114) for instructions. You must use a 12 VDC option for the
Easikey installation. See Easikey Installation and Operation Instructions (P/N : 74-07579-000). Easikey is not for use in UL
installations.
Connect the Easikey door controller to the panel using a D133 Relay Module as shown in Figure 14. Make certain to connect
the common for the Easikey’s 12 VDC supply to the terminal labeled Aux- on the panel.
Figure 14: Easikey Wiring
Arming Devices
Connect to any supervised
point programmed for
Keyswitch (Digit 1 = A, see
Program Entry Guide).
Shorting and restoring point
turns system Off.
Data
+Aux-
Connect the common
for the Easikey's 12 VDC
supply to the terminal
labeled Aux- on the panel.
D133
Relay Module
N/O 1
COMM 1
N/C 1
X1 -
X1 +
End of Line Resistor
+
-
EasiKey Control
P2
To 12 VDC,
Switched
parallel to
door strike.
D2212