Bosch CRC R-1 Installation And Operating Instructions Manual Download Page 4

Product Information

 

Climate Room Control – 6721841498 (2022/04)

60

dangers. Children shall not play with the 
appliance. Cleaning and user 
maintenance must not be performed by 
children without supervision.”
“If the power cable is damaged, it must 
be replaced by the manufacturer, its 
customer service department or a 
similarly qualified person, so that risks 
are avoided.”

2

Product  Information

2.1

Declaration of conformity

The design and operating characteristics of this product 
comply with the European and national requirements.

The CE marking declares that the product complies 
with all the applicable EU legislation, which is 
stipulated by attaching this marking.

The complete text of the Declaration of Conformity is available 
on the Internet: worcester-bosch.co.uk.

2.2

Scope of delivery

The appliances are shown as an example and deviations are 
possible. 
The scope of delivery is shown in Fig. 1. 

[1] wired controller
[2] Communication cable
[3] Fixing materials
[4] Button battery
[5] Set of printed documents for product documentation
[6] Magnet ring
[7] Extension cable (6 m)

The button battery enables the time to be saved following a 
power failure. If the time is not displayed correctly following a 
power failure, the button battery is empty.

2.3

Technical data

Table 26

3

Installation

3.1

Prior to installation

▶ Carefully read the technical documentation of the indoor 

unit, outdoor unit and other system components and 
determine a suitable installation location.

▶ The ambient temperature at the installation location should 

be in the following range: −5...43 °C.

▶ The relative humidity at the installation location should be 

in the following range: 40. 90 %.

▶ Do not install in locations where it is likely to come into 

contact with heavy fuel oil, steam or sulphur gas.

▶ Observe the dimensions of the wired room controller (

 

Fig. 2).

▶ Install it far from heat sources.
▶ Ensure that there is air circulation.

3.2

Mount the wired room controller

NOTICE

Damage to the wired room controller

Opening the wired room controller in the wrong way or 
tightening the screws too tightly can damage it.

▶ Do no exert too much pressure on the wired room 

controller.

▶ Remove the wall plinth of the wired room controller (

 

Fig. 5).
– Insert the tip of a screwdriver at the bending point [1] 

on the rear of the wired room controller. 

– Lift up the screwdriver to lever open the wall plinth [2].

▶ If necessary, prepare the wall and communication wire (

 

Fig. 6).
– [1] Realise putty or insulating material.
– [2] Make an elbow in the cable.

▶ Attach the wall plinth to the wall (

 Fig. 7, [1]).

▶ Fix the wired room controller to the wall plinth (

 Fig. 9).

CRC R-1

Input power voltage

12 V DC

Permissible ambient temperature 
T

amb

−5...43 °C

Permissible relative humidity

40...90%

CRC R-1

Summary of Contents for CRC R-1

Page 1: ...elési útmutató 112 it Istruzioni per l installazione e l uso 123 Climate Room Control CRC R 1 lt Montavimo ir valdymo instrukcija 134 lv Instalācijas un lietošanas instrukcija 145 mk Упатства за инсталација и ракување 156 nl Installatie en gebruikersinstructies 167 pl Instrukcja montażu i obsługi 178 pt Instruções de instalação e funcionamento 189 ro Instrucțiuni de instalare și utilizare 200 sk N...

Page 2: ... and time 62 5 3 Setting main operating mode 63 5 4 Setting the room temperature 63 5 5 Setting timer 63 5 5 1 One time ON OFF timer 63 5 5 2 Weekly ON OFF timer 64 5 5 3 Weekly event timer 64 5 5 4 Additional settings for weekly timer 65 5 6 Setting the swing function 65 5 6 1 Indoor unit with vertical and horizontal swing function 65 5 6 2 Indoor unit with vertical swing function 65 5 6 3 Indoor...

Page 3: ... to comply with instructions may result in material damage and personal injury including danger to life Installation inspections repairs modification and relocation must be donebyaqualifiedinstallerorservice company Before carrying out the installation readtheinstallationinstructionsofall system elements Observe the safety instructions and warnings Follow national and regional regulations technica...

Page 4: ...chnical data Table 26 3 Installation 3 1 Prior to installation Carefully read the technical documentation of the indoor unit outdoor unit and other system components and determine a suitable installation location Theambienttemperatureattheinstallationlocationshould be in the following range 5 43 C The relative humidity at the installation location should be in the following range 40 90 Do not inst...

Page 5: ...nnect the earthing terminal lug Insert the button battery into the holder 1 4 Configuration to the wired room controller Call up the configuration menu and make the settings Switch off the air conditioning system Keep theCOPY key pressed until a parameter appears in the display If several indoor units are detected the address e g 00 appears initially With the or key select an indoor unit 00 16 and...

Page 6: ...oom controller with the address 0 B secondary wired room controller with the address 1 Init ON restore factory settings Key Function K Switch on off M Set operating mode DAYOF F Day off deletion Adjust up down setting Confirm choice TIMER Set timer Fan step d Navigate back Set swing function FUNC Set function COPY Copy adopt data Parameters Description Pos Symbo l Explanation 1 Display of main ope...

Page 7: ...y until appears on the display Press the or key to set the required temperature The fan speed cannot be adjusted in automatic mode Cooling mode Press the M key repeatedly until appears on the display Press the key until the required air speed is reached Press the or key to set the required temperature Dehumidification mode Press the M key repeatedly until appears on the display Press the or key to...

Page 8: ...he display Wait for a few seconds while the setting is saved The unit now starts the next activity cycle following a delay of 1 hour Press the DAY OFF key 3x until 2h appears on the display The unit now starts the next activity cycle following a delay of 2 hours 5 5 3 Weekly event timer Setting timer Up to 8 events can be set for each day to change the operating mode temperature and fan speed Keep...

Page 9: ...coolingmode for an extended period condensate may be discharged Adjusting the louvre by hand may cause faults Only usethe wiredroom control orremote control to adjust the louvre The function and availability of the swing function depends on the indoor unit 5 6 1 Indoor unit with vertical and horizontal swing function Automatic vertical swing mode up down Press the key The symbol appears To cancel ...

Page 10: ...r units rotate Default setting the indoor units rotate every 10 hours Confirm with key Press the or key to set the maximum temperature 26 32 C once the set temperature has been reached both appliances are switched on in cooling mode The Rotation function is interrupted until 24 C has been reached no maximum temperature to interrupt the Rotation function Confirm with key Press the or key to adjust ...

Page 11: ...Assembliescanthereforebe sorted by composition and passed on for recycling or disposal Old electrical and electronic appliances This symbol means that the product must not be disposed of with other waste and instead must be taken to the waste collection points for treatment collection recycling and disposal The symbol is valid in countries where waste electrical and electronic equipment regulation...

Page 12: ...Climate Room Control 6721841498 2022 04 276 1 i 1 2 3 5 4 6 7 0010040461 003 2 120 20 120 60 84 19 46 44 0010035291 001 3 4 0010040476 001 1 2 3 1 2 3 4 0010040477 001 ...

Page 13: ...277 Climate Room Control 6721841498 2022 04 5 6 1 2 0010040394 001 0010035298 001 2 1 1 2 2 1 1 7 8 1 0010040366 001 CN40 1 2 3 0010042010 002 9 1 2 0010040466 001 ...

Page 14: ......

Page 15: ......

Page 16: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...