Bosch CRC R-1 Installation And Operating Instructions Manual Download Page 11

Troubleshooting

67

Climate Room Control – 6721841498 (2022/04)

7

Troubleshooting

7.1

Faults with indication (Self diagnosis 
function)

If a fault occurs during operation, a fault code (e.g. EH b3) 
appears on the display. Refer to the technical documentation of 
the system components for fault codes not listed here.

The wired room controller may display a different fault code to 
the indoor unit, although it is referring to the same fault.

Table 30

8

Environmental protection and disposal

Environmental protection is a fundamental corporate strategy 
of the Bosch Group. 
The quality of our products, their economy and environmental 
safety are all of equal importance to us and all environmental 
protection legislation and regulations are strictly observed.
We use the best possible technology and materials for 
protecting the environment taking account of economic 
considerations.

Packaging

Where packaging is concerned, we participate in country-
specific recycling processes that ensure optimum recycling. 
All of our packaging materials are environmentally compatible 
and can be recycled.

Used appliances

Used appliances contain valuable materials that can be 
recycled. 
The various assemblies can be easily dismantled. Synthetic 
materials are marked accordingly. Assemblies can therefore be 
sorted by composition and passed on for recycling or disposal.

Old electrical and electronic appliances

This symbol means that the product must not be 
disposed of with other waste, and instead must be 
taken to the waste collection points for treatment, 
collection, recycling and disposal.

The symbol is valid in countries where waste 

electrical and electronic equipment regulations apply, e.g. 

"European Directive 2012/19/EC on old electronic and 
electrical appliances". These regulations define the framework 
for the return and recycling of old electronic appliances that 
apply in each country. 

As electronic devices may contain hazardous substances, it 
needs to be recycled responsibly in order to minimize any 
potential harm to the environment and human health. 
Furthermore, recycling of electronic scrap helps preserve 
natural resources. 

For additional information on the environmentally compatible 
disposal of old electrical and electronic appliances, please 
contact the relevant local authorities, your household waste 
disposal service or the retailer where you purchased the 
product.

You can find more information here: 
www.weee.bosch-thermotechnology.com/

Batteries

Batteries must not be disposed together with your household 
waste. Used batteries must be disposed of in local collection 
systems.

Fault code

Possible cause

EH b3

Communication fault between wired room 
controller and indoor unit. Check 
communication cable.

Summary of Contents for CRC R-1

Page 1: ...elési útmutató 112 it Istruzioni per l installazione e l uso 123 Climate Room Control CRC R 1 lt Montavimo ir valdymo instrukcija 134 lv Instalācijas un lietošanas instrukcija 145 mk Упатства за инсталација и ракување 156 nl Installatie en gebruikersinstructies 167 pl Instrukcja montażu i obsługi 178 pt Instruções de instalação e funcionamento 189 ro Instrucțiuni de instalare și utilizare 200 sk N...

Page 2: ... and time 62 5 3 Setting main operating mode 63 5 4 Setting the room temperature 63 5 5 Setting timer 63 5 5 1 One time ON OFF timer 63 5 5 2 Weekly ON OFF timer 64 5 5 3 Weekly event timer 64 5 5 4 Additional settings for weekly timer 65 5 6 Setting the swing function 65 5 6 1 Indoor unit with vertical and horizontal swing function 65 5 6 2 Indoor unit with vertical swing function 65 5 6 3 Indoor...

Page 3: ... to comply with instructions may result in material damage and personal injury including danger to life Installation inspections repairs modification and relocation must be donebyaqualifiedinstallerorservice company Before carrying out the installation readtheinstallationinstructionsofall system elements Observe the safety instructions and warnings Follow national and regional regulations technica...

Page 4: ...chnical data Table 26 3 Installation 3 1 Prior to installation Carefully read the technical documentation of the indoor unit outdoor unit and other system components and determine a suitable installation location Theambienttemperatureattheinstallationlocationshould be in the following range 5 43 C The relative humidity at the installation location should be in the following range 40 90 Do not inst...

Page 5: ...nnect the earthing terminal lug Insert the button battery into the holder 1 4 Configuration to the wired room controller Call up the configuration menu and make the settings Switch off the air conditioning system Keep theCOPY key pressed until a parameter appears in the display If several indoor units are detected the address e g 00 appears initially With the or key select an indoor unit 00 16 and...

Page 6: ...oom controller with the address 0 B secondary wired room controller with the address 1 Init ON restore factory settings Key Function K Switch on off M Set operating mode DAYOF F Day off deletion Adjust up down setting Confirm choice TIMER Set timer Fan step d Navigate back Set swing function FUNC Set function COPY Copy adopt data Parameters Description Pos Symbo l Explanation 1 Display of main ope...

Page 7: ...y until appears on the display Press the or key to set the required temperature The fan speed cannot be adjusted in automatic mode Cooling mode Press the M key repeatedly until appears on the display Press the key until the required air speed is reached Press the or key to set the required temperature Dehumidification mode Press the M key repeatedly until appears on the display Press the or key to...

Page 8: ...he display Wait for a few seconds while the setting is saved The unit now starts the next activity cycle following a delay of 1 hour Press the DAY OFF key 3x until 2h appears on the display The unit now starts the next activity cycle following a delay of 2 hours 5 5 3 Weekly event timer Setting timer Up to 8 events can be set for each day to change the operating mode temperature and fan speed Keep...

Page 9: ...coolingmode for an extended period condensate may be discharged Adjusting the louvre by hand may cause faults Only usethe wiredroom control orremote control to adjust the louvre The function and availability of the swing function depends on the indoor unit 5 6 1 Indoor unit with vertical and horizontal swing function Automatic vertical swing mode up down Press the key The symbol appears To cancel ...

Page 10: ...r units rotate Default setting the indoor units rotate every 10 hours Confirm with key Press the or key to set the maximum temperature 26 32 C once the set temperature has been reached both appliances are switched on in cooling mode The Rotation function is interrupted until 24 C has been reached no maximum temperature to interrupt the Rotation function Confirm with key Press the or key to adjust ...

Page 11: ...Assembliescanthereforebe sorted by composition and passed on for recycling or disposal Old electrical and electronic appliances This symbol means that the product must not be disposed of with other waste and instead must be taken to the waste collection points for treatment collection recycling and disposal The symbol is valid in countries where waste electrical and electronic equipment regulation...

Page 12: ...Climate Room Control 6721841498 2022 04 276 1 i 1 2 3 5 4 6 7 0010040461 003 2 120 20 120 60 84 19 46 44 0010035291 001 3 4 0010040476 001 1 2 3 1 2 3 4 0010040477 001 ...

Page 13: ...277 Climate Room Control 6721841498 2022 04 5 6 1 2 0010040394 001 0010035298 001 2 1 1 2 2 1 1 7 8 1 0010040366 001 CN40 1 2 3 0010042010 002 9 1 2 0010040466 001 ...

Page 14: ......

Page 15: ......

Page 16: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...