2.1.1.3.
Installation Hints
To enable the full performance of the radar sensor, it is recommended to use the following
installation hints and guidelines for the RF integration of the sensor.
Maximum angle between radar cone and fascia
The angle α between the radar beam inside the radar cone and the fascia may not be larger than
80° anywhere inside the radar cone
Figure: Maximum angle between fascia and radar cone
Minimum distance between sensor and fascia
The minimum distance between the sensor radome and the fascia or any other part of the vehicle
may not be smaller than 5 mm.
This is valid for fascia parts fulfilling the following requirements.
Figure: Minimum distance above sensor radome
Vertical tilt of fascia (CR5CP)
The vertical tilt angle between the sensor normal and the surface normal of the fascia shall be in
the range according to the following table.