CM050B

Installer Reference Guide

7

Bosch Security Systems     10/12    CP050B  FTR1.1

N12138

N12138

RoHS

In the interest of ongoing product development this

document is subject to change without notice. 

CP050B Specifications

Part Number:

CP050B -  Night Arm Station 

Operating Voltage:

10.5V D.C - 14.0V D.C. @ 20mA Stand-by, Max 50mA  
(All LED’s and Buzzer Operating)

Module Connection: 

(RS485 LAN)

Max total LAN length using multi strand security cable = 300m ,  

Max total LAN length using 2 pair twisted shielded data cable (Belden 8723) = 1200m.   

See the control panel manual for full wiring instructions.

Operating Environment:

0˚ to 55˚C  RH 5 to 85% at 30˚C non-condensing.

Fixing Method:

The CP050B can be directly installed onto a cavity or plaster wall using appropriate fixings or onto a solid 

masonry or brick wall using a standard height GPO mounting block (Clipsal or Similar).

Warranty:

3 years from date of manufacture (return to base)

Summary of Contents for CP050B

Page 1: ...CP050B Night Arm Station Security System Installer Reference Guide EN Security Systems ...

Page 2: ...r a panic alarm both the PART 1 and PART 2 buttons need to be held down simultaneously for at least two seconds The system sirens and strobes will activate and can only be deactivated by entering a valid user code via the keypad A panic alarm can be activated at any time whether or not the system is already armed Operation Arming and Disarming in PART Mode 1 and 2 With the system in the disarmed s...

Page 3: ... Arm or Disarm Part Mode 2 Press both buttons together for 2 seconds to trigger a Panic Alarm Once an alarm has been triggered you will need to enter a valid code from a keypad to cancel the alarm Status Indicators Press Button to Arm or Disarm Part Mode 1 Figure 1 CP050B Buttons and Indicators CP050B Front Panel Layout ...

Page 4: ...ayed on the status indicators Indicator Brightness The indicator brightness can be adjusted to suit the environment or personal preference To adjust press and hold down the PART 1 button for 2 seconds Both the indicators will come on indicating that the change mode is active Now press the PART 1 key repeatedly to reduce the brightness or the PART 2 key repeatedly to increase the bright ness Once t...

Page 5: ...list of valid module addresses and the corresponding mappings for each module Address Configuration Switch Number SW1 SW2 SW3 Night Arm Station Number Address 1 OFF OFF OFF 1 Address 2 ON OFF OFF 2 Address 3 OFF ON OFF 3 Address 4 ON ON OFF 4 Address 5 OFF OFF ON 5 Address 6 ON OFF ON 6 Address 7 OFF ON ON 7 Address 8 ON ON ON 8 Up to 8 x CP050B can be installed on the Solution 16i and Solution 14...

Page 6: ...system LAN See module connection specification below for more detail Programming Each CP050B is treated by the panel as if it were a standard keypad from the point of view of programming options This means that to change parameters for a Night Arm Station which is configured for address 3 you would need to select Keypad 3 under the devices menu and change the required parameters In a multi area sy...

Page 7: ...le Connection RS485 LAN Max total LAN length using multi strand security cable 300m Max total LAN length using 2 pair twisted shielded data cable Belden 8723 1200m See the control panel manual for full wiring instructions Operating Environment 0 to 55 C RH 5 to 85 at 30 C non condensing Fixing Method The CP050B can be directly installed onto a cavity or plaster wall using appropriate fixings or on...

Page 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2012 Bosch Security Systems CM050BIRG Issue FTR1 1 ...

Reviews: