Installer Reference Guide

2

Bosch Security Systems    10/12    CP050B  FTR1.1

CP050B - Night Arm Station

The CP050B Night Arm Station allows you to arm and disarm the system in either PART Mode 1 or PART Mode 2 
by simply pressing a single button.  Arming in PART Mode automatically disables all zones that you do not wish to 
detect intrusion (e.g. Bedrooms, living rooms etc).  

PART Mode is ideally used at night when you want only the perimeter of the premises to be in a ready state to 
detect intrusion and at the same time allow you to move freely within an area without causing an alarm condition.  
Zones that are to be disabled in PART Mode 1 are programmed by the installer and zones which are to be disabled 
in PART Mode 2 are programmed by the master user.

If an emergency situation arises, the Night Arm Station will allow you to initiate an audible panic alarm.  To trigger 
a panic alarm, both the PART 1 and PART 2 buttons need to be held down simultaneously for at least two seconds.  
The system sirens and strobes will activate and can only be deactivated by entering a valid user code via the keypad.  
A panic alarm can be activated at any time whether or not the system is already armed.

Operation

Arming and Disarming in PART Mode 1 and 2

With the system in the disarmed state (OK indicator illuminated or flashing), press the PART 1 button on the Night 
Arm Station once to arm the system in PART Mode 1 (ON indicator illuminated).  To turn PART Mode 1 OFF, press the 
PART 1 button again and the system will disarm.   

If the entry warning timer is running or an alarm condition occurs while the system was in either PART mode, you 
will not be able to disarm the system using the Night Arm Station.  You will need to enter a valid user code at the 
keypad.
To arm in PART Mode 2, follow the same procedure as above however press the PART 2 Mode button. 

CP050B Compatibility

Panel Type

Supported

Solution 16i

Yes

Solution 16+

No

Solution 64

No

Solution 144

Yes

Summary of Contents for CP050B

Page 1: ...CP050B Night Arm Station Security System Installer Reference Guide EN Security Systems ...

Page 2: ...r a panic alarm both the PART 1 and PART 2 buttons need to be held down simultaneously for at least two seconds The system sirens and strobes will activate and can only be deactivated by entering a valid user code via the keypad A panic alarm can be activated at any time whether or not the system is already armed Operation Arming and Disarming in PART Mode 1 and 2 With the system in the disarmed s...

Page 3: ... Arm or Disarm Part Mode 2 Press both buttons together for 2 seconds to trigger a Panic Alarm Once an alarm has been triggered you will need to enter a valid code from a keypad to cancel the alarm Status Indicators Press Button to Arm or Disarm Part Mode 1 Figure 1 CP050B Buttons and Indicators CP050B Front Panel Layout ...

Page 4: ...ayed on the status indicators Indicator Brightness The indicator brightness can be adjusted to suit the environment or personal preference To adjust press and hold down the PART 1 button for 2 seconds Both the indicators will come on indicating that the change mode is active Now press the PART 1 key repeatedly to reduce the brightness or the PART 2 key repeatedly to increase the bright ness Once t...

Page 5: ...list of valid module addresses and the corresponding mappings for each module Address Configuration Switch Number SW1 SW2 SW3 Night Arm Station Number Address 1 OFF OFF OFF 1 Address 2 ON OFF OFF 2 Address 3 OFF ON OFF 3 Address 4 ON ON OFF 4 Address 5 OFF OFF ON 5 Address 6 ON OFF ON 6 Address 7 OFF ON ON 7 Address 8 ON ON ON 8 Up to 8 x CP050B can be installed on the Solution 16i and Solution 14...

Page 6: ...system LAN See module connection specification below for more detail Programming Each CP050B is treated by the panel as if it were a standard keypad from the point of view of programming options This means that to change parameters for a Night Arm Station which is configured for address 3 you would need to select Keypad 3 under the devices menu and change the required parameters In a multi area sy...

Page 7: ...le Connection RS485 LAN Max total LAN length using multi strand security cable 300m Max total LAN length using 2 pair twisted shielded data cable Belden 8723 1200m See the control panel manual for full wiring instructions Operating Environment 0 to 55 C RH 5 to 85 at 30 C non condensing Fixing Method The CP050B can be directly installed onto a cavity or plaster wall using appropriate fixings or on...

Page 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2012 Bosch Security Systems CM050BIRG Issue FTR1 1 ...

Reviews: