background image

Conettix ITS-D6686-INTL | Installation Guide | 1.0 Introduction 

Bosch Security Systems, Inc. | 11/12 | F01U274797-02 

 

Trademarks 

All hardware and software product names used in 
this document are likely to be registered 

trademarks and must be treated accordingly. 

Copyright  

This document is the intellectual property of 
Bosch Security Systems, Inc. and is protected by 

copyright. All rights reserved. 

1.0

 

Introduction 

The Conettix D6686 Ethernet Network Adapter is 
a two-channel network adapter that supports IP 
Addresses for both IPv4 and IPv6 environments. 
Networked installations can have one if it is only 
used with one D6600 receiver or two configured 
channels when used with a backup D6600 
receiver configuration.

 

 

Follow these instructions to avoid the 
possibility of harm to the operator, or 
damage to the equipment. 

 

1.1

 

Network Interface 

 

Figure 1: Power/Ethernet 

 

1-

 

Ethernet Link LED 

2-

 

RJ45 Ethernet Jack 

3-

 

Ethernet Activity LED 

4-

 

Reset Pin 

5-

 

Power Plug 

 

1.2

 

Serial Interface 

 

Figure 2: D6686 Network Interface 

 

1-

 

Power/Diagnostic LEDs 

2-

 

Serial Port 2 (DTE) – optional (use 

supplied cable if required) 

3-

 

Serial Port 1 (DTE) – use supplied null 

cable 

 

1.3

 

LEDs 

Table

 

1:  D6686 LEDs 

 

LED 

Description 

Power/Diagnostic 

(Blue) 

Steady On: Power OK 

Blinking 2x: No DHCP response 
Blinking 2x: Setup Menu active 

RX Serial 1 Activity 

(Green) 

Off: No data activity 

Blinking: Data received by 
D6686 on Channel 1 

TX Serial 1 Activity 

(Yellow) 

Off: No data activity 

Blinking: Data transmitted from 
D6686 on Channel 1 

RX Serial 2 Activity 

(Green) 

Off: No data activity 

Blinking: Data received by 
D6686 on Channel 2 

TX Serial 2 Activity 

(Yellow) 

Off: No data activity 

Blinking: Data transmitted from 

D6686 on Channel 2 

Ethernet Link 
(Bi-color LED on left) 

Off: No Ethernet link established 

Solid Yellow: 10 Mbps Ethernet 

link established 

Solid Green: 100 Mbps Ethernet 
link established 

Ethernet Activity 

(Bi-color LED on right) 

Off: No data activity 

Solid Yellow: Half Duplex data 

activity 

Solid Green: Full Duplex data 
activity 

Summary of Contents for Conettix ITS-D6686-INTL

Page 1: ...EN Installation Guide Ethernet Network Adapter Conettix ITS D6686 INTL ...

Page 2: ... Serial Interface 3 1 3 LEDs 3 2 0 Installation 4 2 1 Mounting the D6686 4 2 2 Connecting the D6686 4 3 0 Configuring and Programming the D6686 5 3 1 Factory Default IP Address 5 3 2 Identifying the MAC Hardware Address 5 3 3 Obtaining an IP Address 5 3 4 Using the D6200 to configure the D6686 5 3 5 Programming Overview for the D6600 8 4 0 Specifications 9 ...

Page 3: ...J45 Ethernet Jack 3 Ethernet Activity LED 4 Reset Pin 5 Power Plug 1 2 Serial Interface Figure 2 D6686 Network Interface 1 Power Diagnostic LEDs 2 Serial Port 2 DTE optional use supplied cable if required 3 Serial Port 1 DTE use supplied null cable 1 3 LEDs Table 1 D6686 LEDs LED Description Power Diagnostic Blue Steady On Power OK Blinking 2x No DHCP response Blinking 2x Setup Menu active RX Seri...

Page 4: ...necting the D6686 Connect the D6686 as follows Power cable to an available electrical outlet Ethernet cable to network switch RS 232 serial cable to Serial 1 port Refer to the D6600 D6100IPv6 Installation and Operation Guide Network Communication section P N 4998122704 for applications using both serial ports Refer to Figure 3 Figure 3 D6686 Connections 1 Power cable 2 Ethernet cable 3 RS 232 seri...

Page 5: ...s a 128 bit numeric address written as eight groups of four hexadecimal digits separated by colons For example 190 200 128 111 could be an IPv4 address and 2001 0db8 85a3 0042 0000 8a2e 0370 7334 could be an IPv6 address Within an isolated network you can assign IP addresses at random if each one is unique However connecting a private network to the Internet requires using registered IP addresses ...

Page 6: ...address that is listed is shown 6 Select XML Configuration tab and click the Setting button Enter in the Setting dialog D6686 D6100IPv6 IP The IP address recorded in the previous step FTP User Name admin FTP Password PASS Click OK 7 Click the Open XML button select D6686 xml and click Open 8 Make changes to the parameters that are required for your particular installation scenario by selecting the...

Page 7: ...Conettix ITS D6686 INTL Installation Guide 3 0 Configuring and Programming the D6686 Bosch Security Systems Inc 11 12 F01U274797 02 7 ...

Page 8: ...ork interface module DX4020 C900V2 C900TTL E or D9133TTL E must have the proper software version to support encryption For more details refer to the Device Installer Operation and Installation Guide P N 4998138688 3 5 Programming Overview for the D6600 The D6600 Receiver is shipped with factory default program parameters and features already installed Descriptions of the program items are found in...

Page 9: ...ne Formats Characters 7 or 8 data bits Stop bits 1 or 2 Parity Odd even none Modem Controls DTR DSR Flow Control Software XON XOFF Hardware CTS RTS Management FTP SNMP read only Serial login Telnet login System Software Flash ROM standard downloadable from a TCP IP host TFTP FTP or over serial port Diagnostic LEDs Power 10 100 Mb Link on RJ45 10 100 Activity on RJ45 RX Serial 1 Activity TX Serial ...

Page 10: ... 2012 Bosch Security Systems Inc F01U274797 02 Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 9199 800 289 0096 ...

Reviews: