6 720 809 134 (2013/09)
Compress 3000 DW FII
Commissioning | 17
▶ The power connections must be as short as possible in order
to protect the system against overloading; for example,
during a storm.
▶ Connect the appliance to the power supply via a separate
socket with an earth connection.
7
Commissioning
7.1 Before commissioning
▶ Check whether the cylinder is filled with water.
▶ Check all connections for tightness.
▶ Check the electrical connection.
7.2 Switching the appliance on/off
Switching ON
▶ The appliance must be connected to the power supply via a
separate socket with an earth connection.
For the first few seconds after switching on, the display will
not be activated.
Normal start
Switching off
▶ Switch off the appliance at the power connection.
8
Operation
Fig. 13
User interface
[1] Display
[2] Selector keys
NOTICE:
Damage to the appliance!
After installing the appliance in its final
position, wait at least 30 minutes before
switching it on.
NOTICE:
Do not start the appliance without
water!
▶ Only operate the appliance once it has
been filled with potable water.
Once the compressor has been started, the
appliance must run for at least 5 minutes
before it can be switched off again.
Time
Activity
0 - 1 minutes Water temperature check (circulation pump in
operation)
1 - 2 minutes Wait mode
2 - 4 minutes Air temperature check (fan in operation)
> 4 minutes
Compressor in operation
Table 9
NOTICE:
Damage to the appliance!
Minus temperatures can cause the water to
freeze.
▶ Do not interrupt the power supply. This
will ensure that the "frost protection"
function keeps working.
▶ Set the appliance to the "Off" operating
mode (
-or-
▶ Drain the appliance fully.
6720804054-16.1V
1
2
Summary of Contents for Compress 3000 DW FI Series
Page 29: ...6 720 809 134 2013 09 Compress 3000 DW FII 29 Notes ...
Page 30: ...6 720 809 134 2013 09 Compress 3000 DW FII 30 Notes ...
Page 31: ...6 720 809 134 2013 09 Compress 3000 DW FII 31 Notes ...
Page 32: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...