CLIMATE 5000 RAC SINGLE SPLIT (R32) – 6720894076 (2019/08)
37
Troubleshooting
5.2
General Troubleshooting
5.2.1 Error Display (Indoor Unit)
When the indoor unit recognizes one of the errors from the table below,
the operation lamp will flash in a corresponding series, the timer lamp
may turn on or begin flashing, and an error code will be displayed. These
error codes are described in the following table:
Operation
lamp flashes
Timer lamp
LED Display
Error Information
Solution
1 time
OFF
E0
Indoor unit EEPROM parameter error
Page 45
2 times
OFF
E1
Indoor / outdoor units communication error
Page 46
3 times
OFF
E2
Zero-crossing signal detection error
Page 47
4 times
OFF
E3
The indoor fan speed is operating outside of the normal range
Page 48
5 times
OFF
E4
Indoor room temperature sensor T1 is in open circuit or has short
circuited
Page 50
6 times
OFF
E5
Evaporator coil temperature sensor T2 is in open circuit or has short
circuited
Page 50
9 times
OFF
E7
Indoor PCB /Display board communication error
Page 51
7 times
OFF
EC
Refrigerant leak detected
Page 51
1 time
ON
F0
Overload current protection
Page 53
2 times
ON
F1
Outdoor ambient temperature sensor T4 open circuit or short circuit
Page 50
3 times
ON
F2
Condenser coil temperature sensor T3 is in open circuit or has short
circuited
Page 50
4 times
ON
F3
Compressor discharge temperature sensor TP open circuit or short
circuit
Page 50
5 times
ON
F4
Outdoor unit EEPROM parameter error
Page 45
6 times
ON
F5
The outdoor fan speed is operating outside of the normal range
Page 48
1 time
FLASH
p0
IPM malfunction or IGBT over-strong current protection
Page 54
2 times
FLASH
p1
Over voltage or over low voltage protection
Page 55
3 times
FLASH
p2
High temperature protection of IPM module
Page 56
5 times
FLASH
p4
Inverter compressor drive error
Page 57
Table 9.
For other errors:
The display board may show a garbled code or a code which is undefined
by the service manual. Ensure that this code is not a temperature
reading.
Troubleshooting:
Test the unit using the remote control. If the unit does not respond to
the remote controller, replace the PCB of the indoor unit. If the unit
responds, replace the display board.