Technical data
Climate 5000 MS – 6721830162 (2020/12)
38
8
Technical data
Table 18
Outdoor unit Climate 5000 MS ...
14 OUE
18 OUE
21 OUE
27 OUE
When combined with indoor units of the type:
CL3000i UW 26 E
CL3000i UW 26 E
CL3000i UW 26 E
CL3000i UW 26 E
Cooling
Rated output
kW
4.1
5.3
6.2
7.9
Rated output
Btu/h
14000
18000
21000
27000
Power input at rated output
W
1270
1630
1900
2440
Output (min. - max.)
kW
1.4-4.8
2.3-5.6
1.9-6.7
2.2-8.5
Power input (min. - max.)
W
120-1680
120-1980
125-2100
162-3250
Energy efficiency (SEER)
–
6.8
6.1
6.5
6.1
Energy efficiency class
–
A++
A++
A++
A++
Heating
Rated output
kW
4.4
5.6
6.6
8.2
Rated output
Btu/h
15000
19000
22500
28000
Power input at rated output
W
1185
1500
1770
2200
Output (min. - max.)
kW
1.5-4.9
2.4-5.7
1.5-6.7
1.9-8.5
Power input (min. - max.)
W
228-1850
240-1750
250-2000
340-2960
Energy efficiency (SCOP) at –7 °C
–
4.0
4.0
4.0
4.0
Energy efficiency class at –7 °C
–
A+
A+
A+
A+
Energy efficiency (SCOP) at 2 °C
–
5.1
5.1
5.1
5.1
Energy efficiency class at 2 °C
–
A+++
A+++
A+++
A+++
General
Power infeed
V / Hz
220-240 / 50
220-240 / 50
220-240 / 50
220-240 / 50
Max. power consumption
W
2650
2850
3300
3600
Max. current consumption
A
11.5
13.0
15.5
17.5
Refrigerant
– R32
R32
R32
R32
Refrigerant charge
g
1100
1250
1400
1720
Design pressure
MPa
4.3/1.7
4.3/1.7
4.3/1.7
4.3/1.7
Outdoor unit
Flow rate
m
3
/h
2200 2200 3000 2700
Sound pressure level
dB(A)
57
57
61
60
Sound power level
dB(A)
65
65
65
68
Permissible ambient temperature
(cooling/heating)
°C
–15...50/–15...24
–15...50/–15...24
–15...50/–15...24
–15...50/–15...24
Net weight/gross weight
kg
31.8/34.9
35.5/38.5
46.8/51.1
51.1/55.8