Installation Manual
Bosch Climate 5000 AA Series Split Type Ductless Air Conditioner / Heat Pump
| 19
Bosch Thermotechnology Corp.
|
01.2017
Data subject to change
Step 3: Anchor outdoor unit
The outdoor unit can be anchored to to a commercially available mounting pad on
the ground or to a wall-mounted bracket (both sold separately).
Unit mounting dimensions
The following is a list of diff erent outdoor unit sizes and the distance between their
mounting feet. Prepare the installation base of the unit according to the dimensions
below.
WARNING:
Never mount this unit directly on the ground. It must be
anchored according to the guidance provided in these
instructions, and/or local building codes.
W
A
B
D
Air inlet
Air outlet
Air inlet
Figure 24
Outdoor Model
Outdoor Unit Dimensions (mm/in)
Mounting Dimensions
W x H x D
Distance A (mm/in)
Distance B (mm/in)
Climate 5000 AAS-009-0CS, Climate 5000 AAS-009-1CS
770x555x300 (30.3”x21.85”x11.81”)
487 (19.2”)
298 (11.73”)
Climate 5000 AAS-012-0CS, Climate 5000 AAS-012-1CS
800x554x333 (31.5”x21.8”x13.1”)
514 (20.24”)
340 (13.39”)
Climate 5000 AAS-018-1CS
845x702x363 (33.25”x27.63”x14.29”)
540 (21.26”)
350 (13.8”)
Climate 5000 AAS-024-1CS
946x810x420 (37.21”x31.9”x16.53”)
673 (26.5”)
403 (15.87”)
Table 3