Product Information
Climate Class 6000i/8000i – 6721831489 (2021/02)
34
2
Product Information
2.1
Declaration of conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.2
Simplified EU Declaration of Conformity regarding
radio equipment
Bosch Thermotechnik GmbH hereby declares, that the Climate Class
6000i/8000i product described in these instructions complies with the
Directive 2014/53/EU.
The complete text of the EU Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.3
Scope of delivery
Key to Fig. 1:
[1]
Outdoor unit (filled with refrigerant)
[2]
Indoor unit (filled with nitrogen)
[3]
Mounting Plate
[4]
Mirror sheet metal (only for coloured product types
CLC8001i... T/S/R)
1)
[5]
Terminal cover with screw
[6]
Remote control with batteries
[7]
Set of printed documents for product documentation
[8]
Fixing materials (7 long screws, 1 special screw for fixing the
remote control and 8 wall plugs)
[9]
Sheet metal (for fixing the cable in the strain relief)
[10] Drainage connection and drainage tray
(only for product types CLC8001i...)
[11] Drainage connection (only for product types CLC6001i...)
2.4
Product dimensions and minimum clearances
2.4.1
Indoor unit and outdoor unit
Fig. 2
[1]
Wall plug (scope of delivery)
[2]
Special screw (scope of delivery)
A
CLC8001i... model
B
CLC6001i... model
2.4.2
Refrigerant lines
Key to Fig. 3:
[1]
Pipe on gas side
[2]
Pipe on liquid side
[3]
Siphon-shaped elbow as oil separator
If the outdoor unit is positioned higher than the indoor unit, install a
siphon-shaped elbow on the gas side after no more than 6 m and every
6 m thereafter (
Fig. 3, [1]).
▶ Observe maximum pipe length and maximum difference in height
between indoor unit and outdoor unit.
Table 2 Pipe length and difference in height
Table 3 Pipe diameter depending on unit type
Table 4 Alternative pipe diameter
Table 5
1) Fastening the mirror metal sheets
Fig. 10
Maximum pipe
length
1)
[m]
1) Gas side or liquid side
Maximum height
difference
2)
[m]
2) Measured from bottom edge to bottom edge.
All types
≤ 15
≤ 10
Pipe size
Unit type
Liquid side [mm]
Gas side [mm]
All types
6.35 (1/4")
9.53 (3/8")
Pipe diameter [mm]
Alternative pipe diameter [mm]
6.35 (1/4")
6
9.53 (3/8")
10
Specification of the pipes
Min. piping length
3 m
Additional refrigerant if the pipe length
exceeds 7.5 m (liquid side)
CLC6001i...: 15 g/m
CLC8001i...: 0 g/m
1)
1) Prefilled for maximum pipe length of 15 m.
Pipe thickness with 6.35 mm to 12.7 mm
pipe diameter
≥ 0.8 mm
Thickness of insulation against heat
≥ 6 mm
Material of insulation against heat
Polyethylene foam
OBJ_DCL-6721831489-001.fm Page 34 Wednesday, April 21, 2021 2:52 PM