Solar Energy
3.
Bosch Solar Module Electrical Characteristics
Model
Open
Circuit
Voltage
at STC,
(V dc)
Rated
Voltage at
STC,
(V dc)
Maxi-
mum
Sys-
tem
Volta-
ge, (V
dc)
Rated
Current at
STC,
(A dc)
Short
Circuit
Current at
STC,
(A dc)
Rated
Maximum
Power at
STC,
(Watts)
Maximum
Series
Fuse,
(A)
c-Si M 60-225-16
36.0 28.3
600 7.95 8.7 225 15
c-Si M 60-230-16
36.35 28.75
600 8.0 8.75 230 15
c-Si M 60-235-16
36.5 29.35 600 8.0 8.75 235 15
c-Si M 60-240-16
36.7 29.65 600 8.1 8.8 240 15
Module bypass diode type, voltage rating, current rating, and configuration of the diode
Diode Ratings
Module series
Total #
of Dio-
des
Diodes # in par-
allel for each
string
Diode Manufac-
turer
Diode
Type
(A)
(PIV)
c-Si M 60-225-16
3 1
Tyco SL1010
11 40
c-Si M 60-230-16
3 1 Tyco
SL1010
11
40
c-Si M 60-235-16
3 1 Tyco
SL1010
11
40
c-Si M 60-240-16
3 1 Tyco
SL1010
11
40
NOTE:
DO NOT attempt to open the diode housing or junction box located on the back side of any Bosch Solar
module. There are no user serviceable parts inside.
4.
SAFETY INSTRUCTIONS
Handling Safety
DO NOT drop, allow objects to fall on,
or stand or step on modules.
DO NOT install during high winds.
Never leave a module unsupported or
unsecured. If a module falls, the glass
could break. A module with broken
glass cannot be repaired and must not
be used.
DO NOT disassemble the module, or
remove any part installed by Bosch So-
lar. Use modules for their intended use
only and follow all manufacturers’ in-
structions.
DO NOT attempt to remove snow or ice
from the module.
DO NOT direct artificially concentrated
sunlight on the module.
Installation Safety
DO NOT attempt to install or service
any portion of the PV system unless you
understand the electrical operation and
are fully qualified to do so.
3/9