Installation regulations
BT 50 HP – 6 720 821 241 (2017/09)
35
3
Installation regulations
3.1
Regulations
The buffer cylinder must be only be installed and serviced by an
approved contractor in accordance with the respective current version
of the following regulations.
Observe the following directives and standards:
• Local regulations
•
EnEG (Building Regulations)
(in Germany)
•
EnEV (Energy Savings Order)
(in Germany)
Installation and equipment for heating and water heating systems:
•
DIN
and
EN
standards
–
DIN EN 12828
– Heating systems in buildings - Design and installa-
tion of water-based heating systems
–
DIN 18380
– German construction contract procedures (VOB) -
Installation of central heating systems and hot water supply sys-
tems
–
DIN 18381
– German construction contract procedures (VOB) -
Installation of gas, water and drainage systems inside buildings
–
DIN 16297, Part 1/2
– Centrifugal pumps - Wet running pumps
–
EN 12975
– Thermal solar systems and their components
–
EN 12976
– Thermal solar systems and their components
–
ENV 12977
– Thermal solar systems and their components
•
VDE (German Association for Electrical, Electronic & Information
Technologies)
regulations
Product data for energy consumption
•
EU Regulation
and
Directives
–
Directive 2010/30/EU
–
EU Regulation 811/2013
and
812/2013
3.2
Buffer storage tank installation
The buffer storage tank should be installed on a flat floor surface. Ensure
that the bottom of the tank is fully in contact with the floor. Care should
be taken not to damage the metal casing of the tank.
Ensure that the floor is dry and the outside of the storage tank cannot get
wet during its lifetime. The insulation will be damaged if left in contact
with water.
If the buffer storage tank cannot be mounted on a flat floor surface (for
example if the tank is mounted on a wall frame) the tank must first be
placed on top of a suitable metal plate. The bottom of the tank must be
fully in contact with the metal plate and completely cover the tank
bottom.
4
Transport
4.1
Means of transport
▶ Protect the storage tank against tilting and transport to its installation
location standing upright and in its packaging.
▶ Do not remove the storage tank packaging before it is in the
installation location.
Fig. 3
Transport of the hot water storage tank by suitable means
4.2
Industrial location
▶ Observe minimum clearances.
▶ Place storage tank on an even and load-bearing ground.
▶ In damp rooms: put storage tank on a platform.
▶ Recommend minimum clearance of 25mm around the tank.
▶ Ensure you have adequate access to the drain valve.
DANGER:
Risk of injury from carrying heavy weights!
▶ Do not try to lift or carry the storage tank alone.
CAUTION:
Damage from inappropriate protection
during transport!
▶ For transport, use appropriate means, e. g. a sack
truck or pump truck with a tension belt.
NOTICE:
Protect from freezing!
▶ Place storage tank in a frost-proof room.
▶ Ensure the tank is frost protected.
▶ Insulate pipes with class O insulation.
NOTICE:
Damage from corrosion!
▶ Use the storage tank in sealed systems only.
6720803559-03.1Wo