Installation instructions
en
17
12.1 Safe installation
Follow these safety instructions when in-
stalling the appliance.
¡
The appliance can only be used safely if it
is correctly installed according to the safety
instructions. The installer is responsible for
ensuring that the appliance works perfectly
at its installation location.
¡
Check the appliance for damage after un-
packing it. Do not connect the appliance if
it has been damaged in transit.
¡
Before starting up the appliance, remove
any packaging material and adhesive film
from the cooking compartment and the
door.
¡
Never remove the transparent film on the
inside of the door.
¡
Proceed in accordance with the installation
sheets for installing accessories.
¡
Fitted units must be temperature-resistant
up to 90 °C, and adjacent unit fronts up to
65 °C.
¡
Do not install the appliance behind a decor-
ative door or the door of a kitchen unit.
There is a risk of overheating.
¡
Cut-out work on the units should be carried
out before installing the appliance. Remove
any shavings. Otherwise, the correct opera-
tion of electrical components may be ad-
versely affected.
¡
Only a licensed professional may connect
appliances without plugs. Damage caused
by incorrect connection is not covered un-
der the warranty.
WARNING ‒ Risk of injury!
Parts that are accessible during installation
may have sharp edges and may lead to cut-
ting injuries.
▶
Wear protective gloves
WARNING ‒ Risk of fire!
It is dangerous to use an extended power
cord and non-approved adapters.
▶
Do not use extension cables or multiple
socket strips.
▶
If the power cord is too short, contact Cus-
tomer Service.
▶
Only use adapters approved by the manu-
facturer.
12.2 Electrical connection
In order to safely connect the appliance electrically, fol-
low these instructions.
WARNING ‒ Risk of electric shock!
Incorrect installation is dangerous.
▶
Only a qualified electrician may route the socket or
replace a power cable while taking into considera-
tion the applicable regulations.
▶
Connect the appliance only to a correctly installed,
earthed socket.
▶
If the plug is no longer accessible following installa-
tion, an all-pole isolating unit with a contact clear-
ance of at least 3 mm must be available on the in-
stallation side. Contact protection must be ensured
by the installation.
12.3 Scope of delivery
After unpacking all parts, check for any damage in
transit and completeness of the delivery.
12.4 Fitted units
Here, you can find notes on safe installation.
ATTENTION!
Any shavings may impair the function of electrical com-
ponents.
▶
Carry out cut-out work on the units before installing
the appliance.
▶
Remove the shavings.
¡
The minimum installation height is 850 mm.
¡
The installation cabinet must not have a back panel
behind the appliance.
¡
The ventilation slots and intake openings must not
be covered.
¡
Fitted units must be heat-resistant up to 90 °C, and
adjacent unit fronts up to 65 °C.