Technical data | Automax 100 | Basic module TS-AC B1-M2-1X
47/54
Bosch Rexroth AG | 04.2021 | DOK-SUPPL*-TS-AC B1-M2-ITRS-EN-P
Technical data
Technical data - Automax 100 - Basic module TS-AC B1-M2-1X
Designation
Unit
Value
Total weight
kg
3.5
Dimensions
Depth
mm
219,5
Width
mm
364
Height
mm
60,5
Current consumption
1)
A
1.5
Power consumption
2)
W
36
Min. operating temperature
℃
0
Max. operating temperature
℃
+40
Place of installation
---
Closed room
Ambient temperature
℃
+0 to +40
Max. relative air humidity
%
90 at 20 ℃
Max. installation height
m
3000 above sea level
Protection class
IP20
Supply voltage / external power
supply unit
Voltage (DC)
V
24 (±10%)
Current
I
6,5
3)
Module fuse protection
A
6.3
4)
A-weighted continuous sound level (at workplace of
operating personnel)
dB
0
1)
Current consumption of the basic module without extension module and connected actuator.
2)
Power consumption of the basic module without extension module and connected actuator.
3)
Recommended by Bosch Rexroth for operation of the basic module up to its performance limits. Alternatively, a power
supply unit with lower output power can be used. ATTENTION! For this, the total power from basic module, extension
module and actuators to be connected must be determined.
4)
Micro-fuse 5 mm x 20 mm, 6.3 A, version mT (G fuse insert according to IEC 127-2-2).