Conettix Plug-in Communicator Interfaces
Configuration | en
35
Bosch Security Systems, Inc.
Installation and Operation Guide
2017.10 | 09 | F.01U.300.740
Before you begin
–
Separate each ID or value pair with a semi-colon ; (for example,
%1;1=B450;19=1;!
). To
allow spanning of configuration across multiple messages, each SMS starts with the
sequence number followed by the command line separator.
–
Use the ! character to signal the end of the configuration data. Refer to your cellular
phone documentation for available characters.
–
Add the current SMS configuration passcode in the SMS text message to allow the
module to save the new configuration data.
–
The configuration message must begin with the sequence number (%1) and must include
the current B450 configuration password (default = B450) followed by the ID number and
the value you want to set.
–
To remove text from an SMS message, use the word
None
, or
;
. For example, if you want
to remove a SIM PIN using SMS, enter either 4=None or 4=;. The word None is NOT case
sensitive.
SMS configuration parameters
ID
Description
1=
Current passcode (4 to 10 characters);
default = B450
2=
New passcode (4 to 10 characters)
4=
SIM PIN (4 to 8 characters)
Basic parameters
10=
Network Access Point Name (APN): Text characters that can fit in a single text
message
11=
Network Access Point User Name (up to 30 characters)
12=
Network Access Point Password (up to 30 characters)
13=
TCP/UDP port number: 7700 (1 to 65535)
15=
AES encryption
–
0 = disable
–
1 = 128 bit
–
2 = 192 bit
–
3 = 256 bit
16=
AES encryption key (0 to 9, A-F, a-f, based on key size, none, 32, 48, or 64 digits)
Default =
0102030405060708091011121314151601020304050607080910111213141516
19=
Module Enclosure Tamper (V1.0.x control panels on SDI2 bus)
–
0 = disable
–
1 = enabled
20=
Inbound SMS
–
0 = disabled
–
1 = enabled
Advanced parameters