Conettix Plug-in Communicator Interfaces
Configuration | en
29
Bosch Security Systems, Inc.
Installation and Operation Guide
2017.10 | 09 | F.01U.300.740
Notice!
Unsaved changes are lost if you do not press a key within 5 minutes. Tera Term automatically
logs out of the module.
Main Menu options overview
Option
Description
1. Status (Starts
with Basic
Status)
Shows the link, modem, and bus status
2. Change
Passcode
Use to change the login passcode, enter the new passcode twice. The
second entry confirms the new passcode.
Passcodes must be 4 to 10 characters long, and are case-sensitive.
0-9, A-Z, a-z, and special characters are allowed.
Notice!
If SMS configuration is used, do not use semicolon (;) or exclamation
mark (!) as part of the passcode.
3. Basic
Configuration
Use to program Basic Configuration options. Press 0 to return to the Main
menu.
To change a basic parameter, select the option to change, and then enter
in the new value.
4. Advanced
Configuration
Use to program advanced options. Press 0 to return to the Main Menu.
To change an advanced parameter, select the option to change, and then
enter in the new value.
5. Reset to
Factory Defaults
Use to reset all factory default values. All fields are cleared and the factory
default values are restored.
Notice!
A
non-defaulted SDI2 control panel overwrites the default settings if
connected to the defaulted module.
6. Diagnostic
Log
The Diagnostic Log option is used to troubleshoot communication
problems. Only use of the Diagnostic Log option at the direction of Bosch
Technical Support. For more information, refer to
Diagnostic log, page 44
.
7. Firmware
Update
Use to update the B450 firmware. For more information refer to
Firmware
updates, page 38
.
8. Exit
Select to exit the menu and log out. You must enter the passcode to log
back in.
Notice!
If you make configuration changes but do not save the changes, Tera Term
prompts you.
5.3.4
Status menu
Basic Status menu overview
The following section describes the Status menu parameters.