1.
Hold the module mounting brackets on the inside of the enclosure. Match the bracket
holes to a 3-hole mounting pattern on the enclosure
2.
Put the supplied mounting screws through the holes and into the mounting bracket.
3.
Tighten the screws.
4.3
Installing the tamper switch (optional)
Notice!
Dual tamper switch for compatible control panels
For control panels that are compatible with an enclosure tamper switch, you can use this
module to connect and monitor the tamper switch.
1.
Install the ICP-EZTS tamper switch. Use the instructions in the switch installation manual
(P/N: F01U003734).
2.
Connect the wire of the installed tamper switch wire to the tamper switch connector on
the module.
4.4
Installing the cellular antenna
1
2
Callout
ᅳ
Description
1
ᅳ
Plug-in cellular module antenna (routed through any knockout)
2
ᅳ
Antenna cable
1.
Place the magnetic antenna on top of the enclosure, or vertically on another metal
surface.
Notice!
Best performance
If the module has a weak signal, position the antenna on top of a metal surface that has a
radius of 10.16 cm (4 in).