24
Ways of releasing
air outdoors
❏
Connect the diffusion duct to the hot-air
expulsion duct.
❏
Leave the window ajar and feed the
air–expulsion nozzle through the gap. On
windows with double frames, feed the expulsion
nozzle through the gap in the middle.
❏
Close the window as much as possible and
secure it in place using the suction pad provided.
Temporary installation
Permanent installation
The appliance can be installed on a permanent
basis using window/wall Optional Accessory,
reference B1 RKZ 06009, available from your
supplier.
❏
A hole must be made in the wall and the wall
accessory fitted in order to expel hot air.
❏
Store the diffusion duct away and connect the air
expulsion duct to the accessory.
❏
Only the transparent end section of the
accessory is used when air is to be expelled
through a window on a permanent basis. A 10.5
cm. diameter hole must be made in the glass in
order to fit the accessory.
N.B.
• Do not extend the hot-air expulsion duct more
than necessary (maximum length: 140 cm.).
• There must be a distance of at least 70 cm.
between the floor and the end of the duct.
• Do not bend the duct too sharply when
positioning it.
This can impede proper hot-air expulsion, which
may reduce cooling efficiency.