Always perform a thorough and complete calibration to avoid incorrect measuring res-
ults.
– Attach the measuring tool to a vertical surface.
– While the measuring tool is either switched on or off, press and hold the on/off but-
ton
(2)
until the laser beam starts flashing and the light-up ring
(3)
is no longer lit.
– Slowly and evenly rotate the housing of the measuring tool once by more than 360°
(either clockwise or anticlockwise). The rotation should take at least 15 s.
– The calibration process is completed successfully once the light-up ring
(3)
lights up
green.
– If the light-up ring
(3)
lights up red after calibration, the calibration has failed. Restart
the calibration.
Rectifying Errors
Problem
Corrective measures
The light-up ring
(3)
flashes yellow 3 times
during operation, then the measuring tool
switches off.
Replace the battery.
The measuring tool is not within the operat-
ing temperature range specified in the
technical data and switches itself off.
Allow the measuring tool to reach the cor-
rect temperature and switch it back on
once it is back within the operating temper-
ature range.
The gel pad
(14)
does not affix properly.
– Check whether the substrate is suitable
for the gel pad.
– If the gel pad is dirty, it should be
cleaned.
– If the gel pad is damaged, it should be
replaced.
The laser line is not vertical or horizontal as
required after it has been levelled in.
Calibrate the laser line.
Maintenance and Service
Maintenance and Cleaning
Keep the measuring tool clean at all times.
Never immerse the measuring tool in water or other liquids.
Wipe off any dirt using a damp, soft cloth. Do not use any detergents or solvents.