TECHNICAL SPECIFICATIONS
* Measured using Bosch Proximity Card (P/N ACD-ATR11ISO) or
equivalent. Range also depends on electrical environment and/
or proximity to metal.
Suitable for Outdoor Use
Electrical Characteristics
Power Supply Type
Linear type recommended
Operating Voltage Range 10 - 16 VDC
Absolute Maximum (non-
operating)
18 VDC
Maximum Input Current
Standby: 280 mA
Read: 330 mA
Tamper Output
Open collector, active low, max
sink current 30 mA
Max Cable Distance to
Controller
500 ft. (150 meters)
Output modulation
26-bit Wiegand
Card read distance*
23.6 inch (60 cm)
Environmental Characteristics
Operating Temp. Range
-22°F to 145°F (-30°C to 63°C )
Operating Humidity
0 to 95% (non condensing)
Environment class
IP 54
Dimensions
Height x Width X Depth
11.81 x 11.81 x 1.0 inch
(300 x 300 x 25.4 mm)
Weight
2.35 Lbs. (1066 g)