Keypad Indicators
Table 1.2
Keypad Indicators
LCD keypad
indicator icons
LED keypad
indicator lights
Status
Definition
Zone (1-8)
on
Zone is triggered.
off
Zone is normal.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Zone was alarmed or is in alarm
status.
Slow flash (1 second lights on/1
second lights off)
Zone is manually bypassed or
interior Zone is in STAY ARM mode.
AWAY
on
System is armed in AWAY mode.
off
System not armed in AWAY mode.
Slow flash (1 second lights on/1
second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or Code
function mode. STAY indicator
flashes simultaneously.
STAY
on
System is armed in STAY mode.
off
System not armed in STAY mode.
Slow flash (1 second lights on/1
second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or Code
function mode. AWAY indicator
flashes simultaneously.
When bypass function is
performed, the STAY indicator only
flashes.
MAINS
on
AC main power is normal.
Slow flash (1 second lights on/1
second lights off)
AC main power supply failed.
FAULTS
on
System fault or Tamper condition
is present.
off
System is in normal status.
Flashes
System fault or Tamper condition
must be acknowledged.
on
System is disarmed.