S P00 D00 159
2019-03-01
|
Robert Bosch GmbH
60 | ACS 752 | Maintenance
en
14.6 Software update
14.6.1 Firmware
i
The firmware (software) can be updated by way of a
SD card. Further information can be obtained from
customer service.
14.6.2 Vehicle database
i
The vehicle database can be updated annually by
way of a SD card. Further information can be ob-
tained from customer service.
14.8 Changing vacuum pump oil
DANGER – Risk of electric shock from
dangerous voltage!
Electric shocks resulting from contact with
live parts (e.g. master switch, printed cir-
cuit boards) can cause injury, heart failure
and death.
¶
Disconnect the mains plug before open-
ing the ACS 752.
ATTENTION – Risk of burns from hot
surfaces
Contact with the hot vacuum pump surface
will cause severe burns.
¶
Allow the vacuum pump to cool down.
¶
Wear protective gloves.
i
The vacuum pump oil must always be changed
after 10 hours of operation. The prompt
"
Remove the used oil pump
"
appears on the
screen when the vacuum pump oil needs changing.
i
Use the vacuum pump oil (item number
SP00100086) as specified by Bosch.
1
3
2
Fig. 13: Vacuum pump
1 Sight class
2 Oil fill plug
3 Drain plug
14.7 Replacing printer paper
!
Avoid excessive force so as not to damage the
printer cover.
1.
Open the printer cover.
2.
Remove old printer paper roll.
3.
Fit new printer paper roll.
459897_10Rf
1
Fig. 12: Replacing printer paper
1 Printer paper
4.
Close the printer cover.
i
To cut the printer paper correctly, pull the paper
towards the tear bar from one side to another.