1 689 975 252
2019-05-15
|
Robert Bosch GmbH
Service phases | ACS 511 | 19
en
8.7
UV contrast medium filling
i
By default, individual service phases are linked to
other service phases as they are needed to fully per-
form the individual operation selected.
i
The vehicle air conditioning system is partly filled
with UV contrast medium to facilitate detection of
leaks in the event of damage to the vehicle air condi-
tioning system.
i
If "
UV contrast medium filling
" has been selected in
the service process, a defined quantity (time con-
trolled) entered is fed into the vehicle air condition-
ing system along with the refrigerant.
i
EV9 opens and the UV contrast medium (11) is fed
into the vehicle air conditioning system with the
refrigerant.
EV5
EV3
EV6
3
F1
C
P2
HP
5
VU2
6
F2
9
4
EV7
10
7
V1
8
V3
V2
V4
V6
V5
M1
M3
EV10
P
M2
HIGH
LOW
P1
T1
T2
2
EV1
11
VU3
VU1
12
1
EV8
EV9
13
active
Name
Description
1
Fresh oil tank
2
Vacuum pump
3
Expansion valve
4
Evaporator/oil separator
5
Compressor oil separator
6
Compressor
7
Internal refrigerant cylinder
8
Refrigerant cylinder scales
9
Used oil bottle
10
Heat exchanger
11
UV dye bottle
12
Fresh oil scales
13
Used oil scales
EV1
Vacuum solenoid valve
EV3
Flow solenoid valve
Name
Description
EV5
Recovery solenoid valve
EV6
Filling solenoid valve
EV7
Oil drain solenoid valve
EV8
Oil injection solenoid valve
EV9
Contrast medium injection sole-
noid valve
EV10
Solenoid valve for separating
high and low pressure
F1
Coarse filter
F2
Combi filter
HP
High pressure
LP
Low pressure
M1
Low pressure gage
M2
High pressure gage
M3
Internal refrigerant cylinder pres-
sure gage
Name
Description
P1
Pressure sensor
P2
Pressure switch
T1
Low pressure hose
T2
High pressure hose
V1
Tank vapour side hose valve
V2
Tank liquid side hose valve
V3
Tank vapour side valve
V4
Tank liquid side valve
V5
Safety valve
V6
Non condensable drain valve
VU1
Oil non-return valve
VU2
One-way valve
VU3
UV contrast medium non-return
valve