3.2.2
Status display
Figure 3.6:
Dialog button of the controller
The liquid crystal display delivers status information about the controller. Push the dialog
button to switch between different modes.
The selected display mode remains set until the next time the button is pressed. The order of
the display pages is shown in the following table.
Push
Display (Example)
Description
0
AMC-xxxxx
Display firmware variants:
- Bootloader
- WIEGAND
- LBUS
- OSDP
- BG900
- MICOS
(visible from FW-version released after October
2020)
1a
Vaa.bb 01.05.17
FW-version released before October 2020
aa = Reader Protocol Version
37 - Wiegand, 60 - Lbus, 61 - BG900, 62 - OSDP,
63 - MICOS
bb = Firmware Version
01.05.17 release date of the firmware (dd.mm.yy)
1b
Vxx.xx xx.xx.xx
FW-version released after October 2020
Firmware version. The exact format of the version
is product-specific and may vary between product
releases over time.
2
08.24 15:35:15 (S)
Current date and time (mm.yyyy)
(S) = Summer; (W) = Winter
3
Dig. IO: ::::::::::::::::
Display of the digital contacts: the input signals
set will be shown with an extension above - output
signals with an extension below. The first eight
digits display the controller’s signals. The second
eight digits display the extension board’s signals.
3a
Dig. I1: ::::::::::::::::
If there are I/O-Boards connected the signals will
be shown on separate pages.
3b
Dig. I2: ::::::::::::::::
3c
Dig. I3: ::::::::::::::::