Product information
Stora – 6721835341 (2021/04)
32
2.7
Tech data
Table 16 Tech data
2.8
Product data for energy consumption
The following product data satisfy the requirements of the EU
Regulations No. 811/2013 and No. 812/2013 supplementing EU
Regulation 2017/1369.
Manufacturers who implement these guidelines and state the ErP values
are permitted to use the "CE" mark.
Table 17 Product data for energy consumption
Unit
WP 400 PK
WP 500 P
WP 700 P
Dimensions and specifications
-
Fig. 3, page 58
Pressure drop diagram
-
Fig. 4, page 59
General description
Tilt height
mm
1720
2030
2107
Minimum room height for anode replacement
mm
2030
2360
2450
Connection size, DHW
DN
R1"
R1"
R 1¼"
Connection size, cold water
DN
R1"
R1"
R 1¼"
Connection size, circulation
DN
G ¾"
G ¾"
G ¾"
Connection size of cylinder
DN
G 1¼"
G 1¼"
G 1¼"
Connection size of electric heater
DN
G 1½"
G 1½"
G 1½"
Maximum length of electric heater handhole
mm
450
450
600
Connection size of magnesium anode
DN
G 1¼"
G 1¼"
G 1¼"
Inner diameter, test point, cylinder temperature sensor
mm
20
20
20
Inside diameter of handhole
DN
110
110
110
Heat exchanger
Heating water capacity
l
30.0
39.0
49.0
Heating surface
m
2
4.2
5.65
7.0
Maximum heating water temperature
°C
110
110
110
Max. operating pressure, heat exchanger
bar
10
10
10
Maximum continuous output with:
60 °C flow temperature and 45 °C cylinder temperature
l/h
871
1245
1729
kW
35.8
51.3
71.0
Included heating water quantity
l/h
1500
2000
2500
Performance factor
1)
60 °C flow temperature (max. cylinder heat input)
N
L
3.0
3.7
4.5
Minimum heat-up time from 10 °C cold water inlet temperature to 57 °C
cylinder temperature with 60 °C flow temperature:
- 22 kW cylinder heat input
min.
64
78
126
- 11 kW cylinder heat input
min.
128
157
253
Cylinder capacity
Available capacity
l
346
422
680
Available amount of DHW (without reheating
2)
) 57 °C cylinder temperature and
45 °C DHW outlet temperature
l
537
671
940
40 °C DHW outlet temperature
l
465
567
913
Maximum flow rate
L/min
20
20
25
Maximum operating pressure, water
bar
10
10
10
Minimum size of the pressure relief valve (accessory)
DN
20
20
20
1) Rating code N
L
=1 according to DIN 4708 for 3.5 persons, standard bath tub and kitchen sink. Temperatures: cylinder 60 °C, DHW outlet temperature 45 °C and cold water
10 °C. Measured at max. heat output. If the heat output is reduced, N
L
becomes smaller.
2) Excluding distribution losses outside the cylinder.
Product
number
Product type
Cylinder
volume
(V)
Heat
retention
loss (S)
Energy
efficiency
class for
DHW
treatment
8735100975 WP 400 PK 1 C
347,2 l
85,6 W
C
8735100976
WP 500 P 1 C
426,0 l
95,4 W
C
8735100977
WP 700 P 1 C
680,4 l
124,8 W
C
Summary of Contents for 8735100975
Page 57: ...57 Stora 6721835341 2021 04 2 0010037827 001 1 1 13 2 3 4 9 10 11 13 14 12 8 5 6 7 ...
Page 59: ...59 Stora 6721835341 2021 04 4 1 WP 400 PK 2 WP 500 P 0010037816 001 5 6 ...
Page 60: ...Stora 6721835341 2021 04 60 7 8 ...
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...