Solar mode
The water heater will not ignite if inlet water temperature
exceeds the set temperature on the appliance. In this
condition, the solar mode indicator will show on the
LCD display. See Fig. 53, page 35.
Fig. 57
5.5
Use of optional remote control
accessory (part no. TSTAT2)
Fig. 58 Remote control
The wireless remote control accessory (Fig. 80,
component 13) and the temperature selector buttons
on the front of the water heater operate identically.
Contact your distributor to order the remote control
accessory. Modification of the water heaters interior
control unit (Fig. 80, component 16) is required when
programming the remote control with this heater.
5.6
Operation
B
When a hot water tap is opened, main burner ignites
and LCD displays the symbol
.
Fig. 59
B
LCD blinks until selected temperature is reached.
5.7
Reset button
If the LCD shows the error symbol
do not shut off
power or unplug the heater.
See the error code on LCD and consult
“Troubleshooting” section.
Fig. 60
After following instructions indicated in
“Troubleshooting” section.
B
press reset firmly in order to return heater to normal
operation.
Fig. 61 Reset button
If the problem persists, contact your installer.
5.8
Program button
Program button can be used on the appliance and in the
remote control.
Warning:
In applications where inlet water
temperature can exceed 140°F (60ºC), a
thermostatic or mixing valve must be
installed before the appliance to prevent
water exceeding 140°F (60°C) from
entering the appliance.
HOT
BURN
D A N G E R
Water temperature over 125°F can
cause severe burns instantly or
death from scalds.
Children, disabled and elderly are
at highest risk of being scalded.
See instruction manual before
setting temperature at water
heater.
Feel water before bathing or
showering.
6720608643-16.1AL
i
NOTE: up to 6 remote controls can be
programmed for one single water heater,