Product information
|
25
6 720 820 733 (2017/09)
W 500-5X... | W 750-5X... | W 1000-5X...
2
Product information
2.1
Determined use
Enamelled DHW cylinders are designed for heating and storing potable
water. Country-specific regulations, guidelines and standards for
potable water must be observed.
Enamelled DHW cylinders may only be used in sealed unvented systems.
Any other use is considered incorrect. Any damage resulting from non-
intended use is excluded from liability.
2.2
Scope of delivery
500 litre cylinder
• Storage cylinder made of PU rigid foam
• Thermal insulation:
– ErP “B”: additional thermal insulation 40 mm
– ErP “C”: foil jacket on flexible foam underlayer
• Casing lid
• Upper insulation
• Hand-hole cover
• Technical documents
750/1000 litre cylinder
• Storage tank
• PU rigid foam halves
• Thermal insulation:
– ErP “B”: polystyrene jacket, packaged separately
– ErP “C”: foil jacket on flexible foam underlayer
• Casing lid
• Upper insulation
• Floor insulation
• Round hand-hole cover with insulation
• Bag with accessories:
– Rectangular hand-hole cover
– Fleece strip
– Fleece circular blank
– Compass and plug
• Technical documents
2.3
Specification
Requirements
for potable water
Unit
Value
Water hardness
ppm CaCO
3
grain/US gallon
°dH
°fH
> 36
> 2.1
> 2
> 3.6
pH value
–
6.5...9.5
Conductivity
μS/cm
130...1500
Table 2 Requirements for potable water
Unit
W 500-5X B
W 500-5X C
W 750-5X B
W 750-5X C
W 1000-5X B W 1000-5X C
Dimension
Memory
Available capacity (total)
Itr
500
500
768
768
991
991
Usable DHW volume
1)
at
DHW outlet temperature
2)
:
1) Without recharging; set cylinder temperature 60 °C
2) Mixed water at draw-off point (at 10 °C cold water temperature)
45 °C
Itr
714
714
1104
1104
1449
1449
40 °C
Itr
833
833
1288
1288
1690
1690
Maximum cold water flow rate
l/min
50
50
77
77
101
101
Maximum DHW temperature
°C
95
95
95
95
95
95
Maximum operating pressure, potable
water
bar
10
10
10
10
10
10
Highest design pressure
(cold water)
bar
7.8 7.8
7.8
7.8
7.8
7.8
Maximum DHW test pressure
bar
10
10
10
10
10
10
Outputs in conjunction with an external SLP3 (500 litres) or SLP5 (750/1000 litres) heat exchanger
Continuous output
(at 70 °C flow temperature, 45 °C DHW
outlet temperature and 10 °C cold
water temperature)
kW
l/min
160
66
160
66
310
127
310
127
310
127
310
127
Performance factor N
L
3)4)
3) Performance factor NL=1 in accordance with DIN 4708 for 3.5 occupants, standard bath tub and kitchen sink. Temperatures: cylinder 60 °C, DHW outlet temperature 45 °C
and cold water 10 °C. Measured at max. heat output. If the output is reduced, NL becomes smaller.
4) Performance factor NL and continuous output in conjunction with SLP5 primary store system.
kW
55
55
126
126
140
140
Heat-up time at rated output
min
11
11
9
9
11
11
Table 3 W specifications
Summary of Contents for 7735500292
Page 77: ...Stavljanje izvan pogona 77 6 720 820 733 2017 09 W 500 5X W 750 5X W 1000 5X ...
Page 78: ...78 Stavljanje izvan pogona W 500 5X W 750 5X W 1000 5X 6 720 820 733 2017 09 ...
Page 79: ...Stavljanje izvan pogona 79 6 720 820 733 2017 09 W 500 5X W 750 5X W 1000 5X ...
Page 80: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...