6 720 644 951 (2014/11)
330 PN
Appliance details | 7
Fig. 1
3
Appliance details
3.1
330 PN
specifications (Technical data)
Approved in US/Canada
Accessories (Bosch part #)
•
Pressure relief valve (FWL-2)
Safety devices
•
Flame failure device (ionization thermocouple)
•
Over heat prevention (temperature limiter)
•
Pressure relief valve (Available as accessory)
Capacity
Maximum output
BTU/hr
(kW)
58 400 Btu/hr
Maximum input
BTU/hr
(kW)
74 900 Btu/hr
Thermal efficiency
(Efficiency in %)
%
> 78%
Minimum Input
BTU/hr
(kW)
30 735 Btu/hr
Gas Requirement
Gas connection
inches
½ ” NPT
Peak load inlet gas pressure
1)
Table 2
Propane
water
column
10.5” - 14”
Natural Gas
water
column
5.7” - 14”
Water
Hot water connection
inches
½ ” NPT
Cold water connection
inches
½ ” NPT
Capacity
GPM (l/
min)
2.6 (9.8)
Minimum water flow
2)
GPM (l/
min)
0.5 (1.9)
Minimum recommended
water pressure
PSI (bar)
13 PSI (0.9 bar)
Water valve material
Fibreglass -
reinforced
polyamide (PA)
Connections:
Bottom of heater
Dimensions
Depth
inches(mm) 8.66” (220 mm)
Width
inches(mm) 12.20” (310 mm)
Height
inches(mm) 22.83” (580 mm)
Weight
pounds (kg) 26 pounds (12 kg)
Gas types
Natural Gas
LP Gas
Venting
Natural Draft
Minimum height
feet
6* with no elbows
Vertical termination
Vent diameter
(inches)
4”
1) To measure Gas Pressure, see Measuring Gas Pressure,
chapter 4.8, page 19.
2) Activation varies with inlet water temperatures from 0.5 -
1.6 gallon/minute (1.9 - 6.1 l/m).
Table 2
Summary of Contents for 330-PN-L