12
| English
1 609 92A 0JN | (18.6.14)
Bosch Power Tools
Maintenance and Service
Maintenance and Cleaning
Warning! Before any maintenance or cleaning, switch
the glue pen off.
For safe and proper working, always keep the glue pen
clean.
An inserted glue stick
6
may not be removed out of the rear
opening of the glue gun.
After excess glue has hardened, it can be removed with a
blunt object. Do not use solvent for cleaning.
After-sales Service and Application Service
In all correspondence and spare parts orders, please always
include the 10-digit article number given on the type plate of
the glue pen or the charger.
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can al-
so be found under:
www.bosch-pt.com
Bosch’s application service team will gladly answer questions
concerning our products and their accessories.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange
the collection of a product in need of servicing or repair.
Tel. Service: (0844) 7360109
E-Mail: [email protected]
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
City West
Dublin 24
Tel. Service: (01) 4666700
Fax: (01) 4666888
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169
Customer Contact Center
Inside Australia:
Phone: (01300) 307044
Fax: (01300) 307045
Inside New Zealand:
Phone: (0800) 543353
Fax: (0800) 428570
Outside AU and NZ:
Phone: +61 3 95415555
www.bosch.com.au
Republic of South Africa
Customer service
Hotline: (011) 6519600
Gauteng – BSC Service Centre
35 Roper Street, New Centre
Johannesburg
Tel.: (011) 4939375
Fax: (011) 4930126
E-Mail: [email protected]
Glued shoe soles come undone.
Moisture causes leather to swell and
creeps under bonding location.
Adjesive not suitable.
Use specialty adhesive.
Strands/strings of glue are pulled
at the end of the gluing when
removing the glue pen.
Feed still actuated when done applying
the adhesive.
Discontinue feed slightly prior to ending the
adhesive application.
Nozzle not been wiped off.
At the end of gluing before removing the glue pen
from the bonding location, wipe off nozzle
against workpiece.
Workpiece melts.
Workpiece consists of material that
melts at low temperature, e. g. foamed
polystyrene.
Adjesive not suitable.
Use specialty adhesive.
Burns on fingers from applying
adhesive.
Adhesive penetrates through paper
when applying.
Do not hold workpiece in hand.
Apply adhesive with workpiece placed on heat-
resistant silicone pad or base.
Adhesive penetrates through
fabric/tissue when applying.
Do not hold workpiece in hand.
Apply adhesive with workpiece placed on heat-
resistant silicone pad or base.
Metal workpiece has heated up.
Do not hold workpiece in hand.
Apply adhesive with workpiece placed on heat-
resistant silicone pad or base.
Clamp workpiece.
Problem
Cause
Corrective Measure
OBJ_BUCH-1693-002.book Page 12 Wednesday, June 18, 2014 1:45 PM