background image

 English | 

25

Bosch Power Tools

1 609 929 S02 | (19.3.09)

Australia, New Zealand and Pacific Islands

Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169
Customer Contact Center
Inside Australia:
Phone: +61 (01300) 307 044
Fax: +61 (01300) 307 045
Inside New Zealand:
Phone: +64 (0800) 543 353
Fax: +64 (0800) 428 570
Outside AU and NZ:
Phone: +61 (03) 9541 5555
www.bosch.com.au

People’s Republic of China

Website: www.bosch-pt.com.cn

China Mainland

Bosch Power Tools (China) Co., Ltd.
567, Bin Kang Road
Bin Jiang District 310052
Hangzhou, P.R.China
Service Hotline: 800 8 20 84 84
Tel.: +86 (571) 87 77 43 38
Fax: +86 (571) 87 77 45 02

HK and Macau Special Administrative Regions

Robert Bosch Hong Kong Co. Ltd.
21st Floor, 625 King’s Road
North Point, Hong Kong
Customer Service Hotline: +852 (21) 02 02 35
Fax: +852 (25) 90 97 62
E-Mail: [email protected]
www.bosch-pt.com.cn

Indonesia

PT. Multi Tehaka
Kawasan Industri Pulogadung
Jalan Rawa Gelam III No. 2
Jakarta 13930
Indonesia
Tel.: +62 (21) 4 60 12 28
Fax: +62 (21) 46 82 68 23
E-Mail: [email protected]
www.multitehaka.co.id

Philippines

Robert Bosch, Inc.
Zuellig Building
Sen. Gil Puyat Avenue
Makati City 1200, Metro Manila
Philippines
Tel.: +63 (2) 8 17 32 31
www.bosch.com.ph

Malaysia

Robert Bosch (SEA.) Pte. Ltd.
No. 8a, Jalan 13/6
46200 Petaling Jaya,
Selangor,
Malaysia
Tel.: +6 (03) 7966 3000
Fax: +6 (03) 7958 3838
E-Mail: [email protected]
Toll Free Tel.: 1 800 880 188
Fax: +6 (03) 7958 3838
www.bosch.com.sg

Thailand

Robert Bosch Ltd.
Liberty Square Building
No. 287, 11 Floor
Silom Road, Bangrak
Bangkok 10500
Tel.: +66 (2) 6 31 18 79 – 18 88 (10 lines)
Fax: +66 (2) 2 38 47 83
Robert Bosch Ltd., P. O. Box 2054
Bangkok 10501, Thailand
Bosch Service – Training Centre
2869-2869/1 Soi Ban Kluay
Rama IV Road (near old Paknam Railway)
Prakanong District
10110 Bangkok
Thailand

Tel.: +66 (2) 6 71 78 00 – 4
Fax: +66 (2) 2 49 42 96
Fax: +66 (2) 2 49 52 99

OBJ_BUCH-817-004.book  Page 25  Thursday, March 19, 2009  12:32 PM

Summary of Contents for 3 601 K63 1

Page 1: ...tme talimat pl Instrukcja oryginalna cs Původní návod k používání sk Pôvodný návod na použitie hu Eredeti használati utasítás ru Оригинальное руководство по эксплуатации uk Оригінальна інструкція з експлуатації ro Instrucţiuni originale bg Оригинална инструкция sr Originalno uputstvo za rad sl Izvirna navodila hr Originalne upute za rad et Algupärane kasutusjuhend lv Instrukcijas oriģinālvalodā lt...

Page 2: ... Strona 131 Česky Strana 141 Slovensky Strana 150 Magyar Oldal 159 Русский Страница 169 Українська Сторінка 180 Română Pagina 190 Български Страница 199 Srpski Strana 209 Slovensko Stran 218 Hrvatski Stranica 227 Eesti Lehekülg 236 Latviešu Lappuse 245 Lietuviškai Puslapis 255 中文 页 265 中文 頁 273 한국어 면 281 ภาษาไทย หน า 289 Bahasa Indonesia Halaman 298 Tiøng Vi t Trang 308 317 325 v v v v c c c c ΔΤϔ...

Page 3: ...29 S02 19 3 09 Bosch Power Tools Pro fessional OPEN OPEN OPEN OPEN 1 1 2 3 4 5 6 7 9 10 12 14 13 15 16 14 15 13 11 8 18 2 605 438 682 17 1 609 203 X77 OBJ_BUCH 817 004 book Page 3 Thursday March 19 2009 12 32 PM ...

Page 4: ...1 609 929 S02 19 3 09 Bosch Power Tools 4 F E D C B A OBJ_BUCH 817 004 book Page 4 Thursday March 19 2009 12 32 PM ...

Page 5: ... 609 929 S02 19 3 09 Bosch Power Tools 19 20 2 607 002 195 0 601 096 974 2 607 990 031 0 601 015 B00 21 0 601 069 100 0 601 015 A00 L K J I H G OBJ_BUCH 817 004 book Page 5 Thursday March 19 2009 12 32 PM ...

Page 6: ...e ty goggles The laser viewing glasses are used for improved visualisation of the laser beam but they do not protect against laser radiation f Do not use the laser viewing glasses as sun glasses or in traffic The laser viewing glass es do not afford complete UV protection and reduce colour perception f Have the measuring tool repaired only through qualified specialists using original spare parts T...

Page 7: ...ass 2 Laser type 635 nm 1 mW C6 1 Shortest pulse duration 1 1600 s Tripod mount 1 4 Batteries 3 x 1 5 V LR6 AA Operating life time approx 12 h Automatic switch off after approx 30 min Weight according to EPTA Procedure 01 2003 0 45 kg Dimensions 118 x 57 x 89 mm Degree of protection IP 54 dust and splash water protected Please observe the article number on the type plate of your measuring tool The...

Page 8: ...ide of the battery compartment When the battery indication 5 flashes red the batteries must be replaced Always replace all batteries at the same time Only use batteries from one brand and with the identical capacity f Remove the batteries from the measuring tool when not using it for extended periods When storing for extended periods the bat teries can corrode and discharge themselves Operation In...

Page 9: ...utton 4 All three operating modes can be selected either with or without automatic levelling Pulse Function When working with the laser receiver 21 the pulse function must be activated independent of the selected operating mode In pulse function the laser lines flash at very high frequency and thus become detectable for the laser receiver 21 To switch on the pulse function press button 3 When the ...

Page 10: ...ic influences such as heavy impact or falling down can lead to deviations Therefore check the accuracy of the measuring tool each time before starting your work First check both the height as well as the level ling accuracy of the horizontal laser line then the levelling accuracy of the vertical laser line Should the measuring tool exceed the maximum deviation during one of the tests please have i...

Page 11: ... culated as follows dmax double distance of the walls x 0 3 mm m Example With a 5 metre distance between the walls the maximum deviation must not exceed dmax 2 x 5 m x 0 3 mm m 3 mm Thus the marks must not be more than 3 mm apart Checking the Levelling Accuracy of the Horizontal Line For the check a free surface of approx 5 x 5 metres is required Set up the measuring tool on a firm level sur face ...

Page 12: ...peration mode and direct the laser beams at the door opening Mark the centre of the vertical laser line at the floor of the door opening point I at a distance of 5 metres beyond the other side of the door opening point II and at the upper edge of the door opening point III Position the measuring tool on the other side of the door opening directly behind point II Allow the measuring tool to level i...

Page 13: ...s a stable height adjustable meas uring support Place the measuring tool via the tripod mount 6 onto the 1 4 male thread of the tripod and screw the locking screw of the tripod tight Working with the Laser Receiver Accessory see figure G Under unfavourable light conditions bright environment direct sunlight and for larger distances use the laser receiver for improved finding of the laser lines 21 ...

Page 14: ...ar and pay attention to any fluff of fibres If the measuring tool should fail despite the care taken in manufacturing and testing procedures repair should be carried out by an authorized after sales service centre for Bosch power tools Do not open the measuring tool yourself In all correspondence and spare parts orders please always include the 10 digit article number given on the type plate of th...

Page 15: ...om cn Indonesia PT Multi Tehaka Kawasan Industri Pulogadung Jalan Rawa Gelam III No 2 Jakarta 13930 Indonesia Tel 62 21 4 60 12 28 Fax 62 21 46 82 68 23 E Mail sales multitehaka co id www multitehaka co id Philippines Robert Bosch Inc Zuellig Building Sen Gil Puyat Avenue Makati City 1200 Metro Manila Philippines Tel 63 2 8 17 32 31 www bosch com ph Malaysia Robert Bosch SEA Pte Ltd No 8a Jalan 13...

Page 16: ...ic Equipment and its implementation into national right measuring tools that are no longer usable must be collected separately and disposed of in an environmentally correct manner Battery packs batteries Do not dispose of battery packs batteries into household waste fire or water Battery packs batteries should be collected recycled or dis posed of in an environmental friendly manner Only for EC co...

Reviews: