![Bosch Rexroth MCR 30 Series Instruction Manual Download Page 19](http://html.mh-extra.com/html/bosch-rexroth/mcr-30-series/mcr-30-series_instruction-manual_2791054019.webp)
About this product 19/56
RE 15215-01-B/11.2015, MCR Series 30, 31, 32, 33 and 41,
Bosch Rexroth AG
cooling of the hydraulic fluid. The flushing feature incorporates a relief valve which
is used to maintain a minimum boost pressure and operates at a standard setting of
14 bar.
Different orifice sizes may be used to select varying flows of flushing fluid between
1.6 to 14 l/min (based on a boost/charge pressure of 25 bar). For all available
options refer to flushing information sheet 15225-01.
A (B)
B (A)
Fig. 6: Flushing schematic
nOTICE!
Danger from improper use of the holding brake!
Product can be damaged!
▶
The holding brake is designed solely for static use and should not be applied
whilst the motor is rotating.
Fig. 7: Holding brake section
As a safety requirement in mobile applications a parking brake may be provided to
ensure that the motor cannot turn when the machine is not in use.
The brake is mounted by the way of the rear case (
2
) and brake shaft (
16
).
A disc pack (
11
), with alternate discs splined to the brake shaft and brake housing,
is compressed by the force of a disc spring (
10
) acting through a piston (
12
). The
friction between the discs generates a holding torque.
Holding brake
(multi-disc brake)
2
9
12
10
11
14
15
13
16
Z