12.2.1 Switching times without devices at the USB ports
Switching condition
Switching time in standard USB
mode
Switching time in extended USB
mode
Switching to an other operator
display
Up to 10 seconds
Up to 20 seconds
Tab. 12-4: Switching times without devices connected to the USB ports
12.2.2 Switching times with devices to the USB ports
Switching condition
Switching time in standard USB
mode
Switching time in extended USB
mode
Switching to an operator display
at which only already known USB
devices are connected to the
same USB port
Up to 5 seconds
Up to 10 seconds
Switching to an operator display
at which a new USB device has
been connected
Up to 30 seconds
(Period until the new USB device
is correctly installed by Win-
dows)
Up to 30 seconds
(Period until the new USB device
is correctly installed by Windows)
Tab. 12-5: Switching times with devices connected to the USB ports
If the disabled operator display is not in the "Energy Save Mode", the
devices connected to the USB ports XUSBx can still be operated for
three seconds. The key operation and touch operation of the dese-
lected operator display is disabled immediately.
12.3 Display elements
There are five LEDs on the Y-repeater (see
fig. 9-1 "Connector panel of the Y-re-
). The LEDs indicate the current operating state.
LED
Meaning
Vin
Display of the 24 V voltage supply
XVID1
XSER1
Operating state, operator display 1
XSER2
XVID2
Operating state, operator display 2
Tab. 12-6: LEDs at the Y-repeater
12.4 Operating and error display
Start the measures specified in the following table if one of the LEDs is on.
Y-Repeater
Bosch Rexroth AG
Device description
DOK-SUPPL*-VAC*01*****-IT03-EN-P