Safety Instructions
Please read "Precautions" carefully before operating your dehumidifier.
The warnings and the cautions stated in "Precautions" must be observed for safe operation.
• In case of any abnormality, be sure to turn off the dehumidifier, disconnect the plug and make contact to the seller of your appliance. (Abnormal operation
may result in a failure of the unit, electric shock, fire, etc.).
• Never attempt to turn off the dehumidifier by disconnecting the plug.
• Never modify the dehumidifier. Do not attempt to disassemble or service the unit by yourself.
• Keep your hands dry while plugging into or pulling off the plug to avoid electric shock.
• AC220-240 volt of alternating current is applied to this equipment.
• Remove any dust from the blades of the power plug and insert the plug into an outlet securely.
• To avoid the risk of fire or explosion, do not spray to the dehumidifier. Do not put any inflammables or chemicals near the unit.
• To prevent resin parts from melting or catching on fire, do not place the dehumidifier near heating appliances.
• Do not connect the dehumidifier to an outlet having the electrical ratings below the dehumidifier's.
• The power cord must not be damaged or modified. Do not put any hot or heavy thing on the cord. Do not pull it out , or bundle it during operation.
• To avoid damages to the power cord, do not pinch the cord in a door.
• Never put rods or objects into the openings of the dehumidifier. Because this unit contains a fan running at high speed, contact with the moving fan may
cause an accident.
• Remove water that has been collected in the tank. (Accidentally drinking of the water or using it for other purpose may cause illness and /or unforeseen
accidents).
• Risk of electric shock! Disconnect power before servicing unit ! Moving parts! Do not operate unit with back cover removed. Hot parts. Do not operate unit
with back cover removed.
• Risk of electric shock! Switch in off position does not de-energize all loads.
• Correct Disposal
WARNING!
Do not use means to accelerate the defrosting process or to clean, other than those. Recommended by the manufacturer
The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operat-
ing electric heater.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
– Maximum refrigerant charge amount: 30g
• The appliance shall be installed in accordance with national wiring regulations.
• If the supply cord is damaged, it must be replaced by an authorized service department.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
• Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
• The dehumidifier must be used on a level and stable surface.
• To prevent the water from freezing, do not use the dehumidifier and the drain hose at ambient temperature below 0⁰C.
• Do not use the dehumidifier outside. Exposure to direct sunlight or rain may result in overheating, electric shock and fire.
• Do not use the dehumidifier outside. Exposure to direct sunlight or rain may result in overheating, electric shock and fire.
• Do not put water vessel on the dehumidifier (In case of any spill of water, the water gets into the unit and deteriorates the insulation.)
• Never attempt to use the dehumidifier for special uses, such as food or preservation of art objects, or the like. The deterioration of preserving quality may
be caused.
• Do not use the dehumidifier where any leakage of oil or flammable gas may take place.
• Do not use the unit in places subject to chemicals.
• For continuous draining, make sure that the drain hose is set properly without a rising slope.
• Be careful that a heating appliance is not exposed to the wind from the dehumidifier.
• Do not use the dehumidifier as a chair or a footstool.
• For safety purpose, disconnect the power plug if the unit is not use for a long time.
• Be sure to take hold of the power plug when plugging in and out of an outlet.
• In case of using the dehumidifier in a closet, be sure to prevent children from getting in the closet.
• Do not remove the float lever from the water tank.
• To avoid damages to the power cord, do not pull out the cord when moving the unit.
• Do not block up the air intakes and the air outlets. Do not cover the unit with washed clothes.
• Prior to continuous operation for a long duration, periodical checking is required especially for the air clean filter, the drain hose, or the like.
• Turn off the unit and disconnect the power plug before starting any cleaning or other routine maintenance.
•To avoid the risk of electric shock, never sprinkle or spill water on the dehumidifier when cleaning.
• Turn off the unit and empty the water out of the water tank when moving the unit. Be sure to hold the handle when moving.
CAUTION! RISK OF FIRE!
Technical Data
Voltage/Frequency:
220-240V/50HZ
Power:
420W
Screen type:
LED
Air filter type:
Carbon filter
Refrigerant fluid type:
R290
Dehumidication capacity:
20L/day
Summary of Contents for 030751
Page 1: ...Art Nr WWW BORMANNTOOLS COM en User Manual el v2 1 BEH2800 030751...
Page 9: ...WWW BORMANNTOOLS COM 9 GR AC 220 240 volt 30g Service 8 0 C...
Page 10: ...WWW BORMANNTOOLS COM 10 GR ON OFF max 70 Service...
Page 12: ...WWW BORMANNTOOLS COM 12 GR 1 2...
Page 13: ...WWW BORMANNTOOLS COM 13 GR 1 2 3 4 20 0 24 0 24 Hr 24 1 24 1 3 36 C...
Page 14: ...WWW BORMANNTOOLS COM 14 GR ON OFF 1 2 3 2 2...
Page 15: ...WWW BORMANNTOOLS COM 15 GR EL Service...
Page 16: ...DISPOSE OF PACKAGING RESPONSIBLY DO NOT DISPOSE OF ELECTRICAL GOODS IN HOUSEHOLD WASTE...