Borg & Overström
GB
19
Install & Operation Manual
For this we recommend the use
of Bioguard Foam Descaler &
Sanitiser Spray.
Turn off water and remove the
service filter. Retain service filter
for reuse.
When the external cleaning
(minimum 5 minutes) is completed,
flush the machine using the cold
button with clean water until the
dispense water runs clear. Repeat
briefly with the ambient and
sparkling buttons if present.
Fit new filter. Turn on incoming
water supply and reconnect the
power.
10
12
11
13
Pre-flush the new filter to waste
using the ambient button until
the water appears clear and is
free of air. Flush through a small
amount of water to check all
functions.
Pay particular attention to the
dispense faucet and the push
button controls. For this use
Bioguard External Sanitiser &
Clear Spray and Sanitising
Wipes.
Attend to any cosmetic marks
with Bioguard Rejuvenator &
Protector as needed.
Remember to include the drip
tray. If a Waste Overflow
System is fitted, empty this
and flush through with a small
amount of sanitisation fluid if
needed.
15
14
16
17
Please note that this sanitisation fluid contains an
active caustic/alkaline agent.
Always use responsibly and with care remembering
that due to its alkaline nature unnecessary
concentrated/prolonged contact with any materials,
including metals, can cause damage. Always rinse
all contact surfaces after use with clean water.
Avoid skin contact and wear
protective gloves when
handling sanitisation fluids.
In the event of any skin
contact, flush immediately
with clean, cold water.
5
mins
PINK
5
mins