1 Safety Precautions

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all 

safety messages that follow this symbol to avoid possible injury or death.

This mark indicates procedures which, if improperly performed, might lead to the death or serious 

injury of the user.

This mark indicates procedures which, if improperly performed, might possibly result in personal 

harm to the user, or damage to property.

NOTICE is used to address practices not related to personal injury.

1) Instructions for installation and use of this product are provided by the manufacturer and accompany each unit. 

The instruction of installation, maintenance and operating and safety instructions shall be included.

2) Installation  must  be  performed  in  accordance with  the  requirements  of  NEC  and  CEC  by  authorized  personnel 

only.

3) Before  installation,  please  check  if  the  power  supply  is  in  accordance with  the  requirements specified  on  the 

nameplate. And also take care of the power safety.

4) Make  sure  the  unit can  be  earthed  properly  and soundly  after  plugging  into  the  socket so  as  to  avoid  electric 

shock. Please do not connect the ground wire to gas pipe, water pipe, lightning rod or telephone line.

5) Be sure to use the exclusive accessory and part to prevent the water leakage, electric shock and fire accidents.

6) If refrigerant leakage happens during installation, please ventilate immediately. Poisonous gas will emerge if the 

refrigerant gas meets fire.

7) Wire  size  of  power  cord  should  be  large  enough.  The  damaged  power  cord  and  connection  wire  should  be 

replaced by exclusive cable.

8) After connecting the power cord, please fix the electric box cover properly in order to avoid accident.

9) Never fail to comply with the nitrogen charge requirements. Charge nitrogen when welding pipes.

10) Never short-circuit or cancel the pressure switch to prevent unit damage. 

11) Please firstly connect the wired controller before energization, otherwise wired controller can not be used.

12) Before using the unit, please check if the piping and wiring are correct to avoid water leakage, refrigerant leakage, 

electric shock, or fire etc.

13) Do not insert fingers or objects into air outlet/inlet grille.

14) Open  the  door  and  window  and  keep  good  ventilation  in  the  room  to  avoid  oxygen  deficit  when  the  gas/oil 

supplied heating equipment is used.

15) Never start up or shut off the air conditioner by means of directly plug or unplug the power cord.

16) Turn off the unit after it runs at least five minutes; otherwise it will influence oil return of the compressor.

17) Do not allow children operate this unit.

18) Do not operate this unit with wet hands.

19) Turn  off the  unit  or cut  off  the  power supply  before cleaning  the  unit,  otherwise  electric  shock  or  injury  may 

happen.

20) Never spray or flush water towards unit, otherwise malfunction or electric shock may happen.

21) Do not expose the unit to the moist or corrosive circumstances.

22) Electrify  the  unit  8  hours  before  operation.  Please switch  on for  8  hours  before  operation.  Do  not cut  off  the 

power when 24 hours short-time halting (to protect the compressor). 

23) Volatile  liquid, such as diluent or gas will damage the unit appearance. Only use soft cloth with a little neutral 

detergent to clean the outer casing of unit.

24) Under cooling mode, please don't set the room temperature too low and keep the temperature difference between 

indoor and outdoor unit within 41

25) If  anything  abnormal  happens  (such  as  burning  smell),  please  power  off  the  unit  and cut  off  the  main  power 

supply, and then immediately contact appointed service center. If abnormality keeps going, the unit might be 

damaged and lead to electric shock or fire.

26) User is not allowed to repair the unit. Fault service may cause electric shock or fire accidents. Please contact  

appointed service center for help. 

Summary of Contents for Brisa MBRS42HPJ1OA

Page 1: ...For proper operation please read and keep this manual for future reference If you have lost the Owner s Manual please contact the local agent or visit www borealintl com or send an email to borealsale...

Page 2: ...e normal condition by harmonizing their running modes the cooling mode is compatible with the dehumidifying mode and the fan mode can go with any other mode If the supply power fails when the unit is...

Page 3: ...n of such waste separately for special treatment is necessary Exception Clauses Manufacturerwillbearnoresponsibilitieswhenpersonalinjuryorpropertylossiscausedbythefollowingreasons 1 Damagetheproductdu...

Page 4: ...3 3 Piping Connection 7 4 Installation Instruction 8 4 1 Outline and dimension of the outdoor unit 8 4 2 Installation of the Connection Pipe 9 4 3 Air Purging and Refrigerant Charge 11 4 4 Electric Wi...

Page 5: ...pes 10 Never short circuit or cancel the pressure switch to prevent unit damage 11 Please firstly connect the wired controller before energization otherwise wired controller can not be used 12 Before...

Page 6: ...eries 2 We are not responsible of personal injury or equipment damage caused by improper installation and commission unnecessary service and incapable of following the rules and instructions listed in...

Page 7: ...roduct lineup is provided with capacity range from 30KBtu to 42KBtu which can be widely used in boarding house and working area and especially applicable to the place with variable load change Our com...

Page 8: ...drive up to five indoor units which can be cassette type duct type wall mounted or floor ceiling type The outdoor unit will run as long as any one indoor unit receives the running command and all indo...

Page 9: ...before outgoing 2 The parameters below are tested under rated working condition If there is any change to them please refer to the nameplate 3 The parameters of heating capacity of indoor unit for hea...

Page 10: ...orrosive gas or exhaust gas 4 Leave some space for heat exchanging and servicing so as to guarantee unit normal operation 5 Keep the indoor and outdoor units close to each other as much units close to...

Page 11: ...oor Unit and Outdoor Unit ft Liquid Gas 30K 1 4 3 8 229 6 When the outdoor unit is above maximum height difference between indoor and outdoor units is up to 49 2ft When the indoor unit is above maximu...

Page 12: ...ee match series 8 4 Installation Instruction 4 1 Outline and dimension of the outdoor unit MBRS42HPJ1OA Outline dimension and Mounting holes Fig 5 40 42 1 2 24 5 6 17 1 3 14 1 4 15 3 4 43 3 7 Unit inc...

Page 13: ...never pull any joints of the indoor unit by force otherwise the capillary pipe or other pipe may crack which then would result in leakage 2 The refrigerant pipe should be supported by brackets that i...

Page 14: ...nd plastic tape in order to prevent condensation and water leakage 2 The joints of the indoor unit should be wrapped with the insulating material and no gap is allowed on the joint of the indoor unit...

Page 15: ...rging 1 The refrigerant has been charged into the outdoor unit before shipment while additional refrigerant still need be charged into the refrigerant pipe during the field installation 2 Check if the...

Page 16: ...ot pull the power cord by force 4 The electric installation should be carried out by the technician as instructed by the local laws regulations and also this manual 5 The diameter of the power cord sh...

Page 17: ...nnect well according to the instruction 3 The electric installation should be carried out by the technician as instructed by the local laws regulations and also this manual 4 The installation location...

Page 18: ...test It may cause insufficient cooling heating capacity Is the unit get proper thermal insulation It may causecondensation and dripping Does the unit drain well It may causecondensation and dripping I...

Page 19: ...blown out again NOTICE If problem can not be solved after checking the above items please contact service center and show phenomena and models Following circumstance are not malfunction Table 11 Malfu...

Page 20: ...hat of outdoor unit indoor fault indicator will flash and conflict will be shown on the wired controller after 5 minutes Indoor unit stops to run and meanwhile change outdoor operating mode as the sam...

Page 21: ...h 3 times Outdoor ambient sensor malfunction Flash 6 times Outdoor tube sensor malfunction Flash 5 times Exhaust sensor malfunction Flash 7 times Attain the temperature of switch on Flash 8 times Freq...

Page 22: ...remote wireless controller has been replaced 4 Check if the filter screen has been set soundly 5 After long period of shutdown open the main power switch 8 hours before re operating the unit so as to...

Page 23: ...agency designated by us Warranty should meet the following requirements 1 First run of the unit should be operated by professional personnel from appointed service center 2 Only our manufactured acces...

Page 24: ...Boreal International a Watsco Inc subsidiary borealsales borealintl com www borealintl com 10300 NW 19th St 105 Doral FL 33172 786 621 8250 66129935471...

Reviews: