Cleaning and maintenance
www.bora.com
i
If the cover flap is not properly installed in its locking
mechanism, it will not close fully.
i
If the grease filter or cover flap are not fitted properly, the
control knob display shows an error message
E 0 1 2
or
E
0 1 3
(see the Troubleshooting chapter).
Removing the maintenance tray
i
The maintenance tray cannot be removed in the following
installation situations: single installation, 2nd adjacent
extractor, adjacent wok cooktop.
i
To remove the maintenance tray, the grease filter and
filter tray must be removed first.
2
1
Fig. 8.4
Removing the maintenance tray
[1]
Maintenance tray
[2]
Lock
X
X
Turn the two levers of the lock [2] outwards 90° to unlock the
maintenance tray [1].
X
X
Lift the maintenance tray [1] out of the cooktop extractor.
Installing the maintenance tray
Fig. 8.5
Installing the maintenance tray
Fitting the cover flap, grease filter and filter tray
Fig. 8.2
Fitting the components
X
X
If necessary, activate the cooktop extractor cleaning function.
X
X
Insert the filter tray in the opening on the extractor.
X
X
Insert the grease filter into the opening in the extractor.
X
X
Ensure that the grease filter sits correctly in the gap in the
housing.
Fitting the cover flap:
1
2
3
Fig. 8.3
Fitting the cover flap
[1]
Extractor opening
[2]
Holder
[3]
Cover flap
X
X
Lay the cover flap [3] on its side next to the extractor opening
[1].
X
X
Allow the cover flap [3] to slide diagonally into the holder [2].
X
X
Press the ends of the cover flap [3] lightly from above until you
hear them click into place.
X
X
Make sure that the cover flap [3] has been fitted correctly.