![bora Professional PKA3 Operating Instructions Manual Download Page 32](http://html1.mh-extra.com/html/bora/professional-pka3/professional-pka3_operating-instructions-manual_2788245032.webp)
EN
32
Functions and operation
www.bora.com
Activating the automatic heat up function
X
X
Open the cooktop function menu.
X
X
Do the following:
1
2
3
4
Fig. 6.37
Activating the automatic heat up function
X
O
An acoustic signal is heard, the automatic heat up function is
activated and the corresponding timer counts down.
X
O
The heat-up symbol
A
and the set power level are shown in
the control knob display (e.g.
A 5
).
Deactivating the automatic heat up function early
The activated automatic heat up function will end prematurely if
you
X
X
reduce the power level (continuous cooking level);
X
X
set the power level
9
;
X
X
activate the power setting
ßp
;
X
X
activate the heat retention level
v
;
X
X
switch off the cooktop.
Time lapsed
X
O
When the heat up time has lapsed, the previously set
continuous cooking level will be activated.
X
O
An acoustic signal is heard.
X
O
The heat up symbol will no longer be displayed
6.6.4 Automatic heat up function
(not on PKT3)
When the automatic heat up function is activated, the cooking
zone works at full power for a certain time and is then
automatically reset to the previously set level.
The system automatically determines the heating time
depending on the power level set.
PKFI3, PKI3, PKIW
Power level (continuous cooking
level)
Cooking times in min:sec
1
00:40
2
01:00
3
02:00
4
03:00
5
04:20
6
07:00
7
02:00
8
03:00
Tab. 6.9
Overview of heating times
PKC3, PKCB3, PKCH3
Power level
(continuous cooking level)
Cooking times in
min:sec
1
01:00
2
03:00
3
04:48
4
06:30
5
08:30
6
02:30
7
03:30
8
04:30
Tab. 6.10
Overview of heating times
i
If the cooking zone power level is increased while the
automatic heat up function is active, the automatic heat
up function remains active. The heating time is adjusted
accordingly.
i
If the cooking zone power level is decreased while the
automatic heat up function is active, the automatic heat
up function is deactivated.
Requirement for the automatic heat up function:
X
O
cooking session with a power level between 1 and 8.
Summary of Contents for Professional PKA3
Page 45: ...EN 45 Notes www bora com 11 Notes...
Page 46: ...EN 46 Notes www bora com...
Page 47: ...EN 47 Notes www bora com...