bora Professional PKA3 Operating Instructions Manual Download Page 1

EN

P3XUMEN-100

www.bora.com

Operating instructions BORA Professional 3.0 system

Cooktop extractor and cooktops

1044130 - 48

Summary of Contents for Professional PKA3

Page 1: ...EN P3XUMEN 100 www bora com Operating instructions BORA Professional 3 0 system Cooktop extractor and cooktops 1044130 48...

Page 2: ...educing the power level 27 Setting the temperature on the Tepan stainless steel grill PKT3 27 6 5 4 Cooktop power setting 27 6 5 5 Bridging function only on PKFI3 and PKT3 28 Activating the bridging f...

Page 3: ...ntion function 30 Increasing or reducing the active heat retention level 30 Deactivating the heat retention function 30 6 6 3 Timer function automatic cut off not on PKT3 31 Activating cooking zone ti...

Page 4: ...gnal words These instructions contain important information to protect you from injury and prevent damage to the appliance Please read these instructions carefully before installing or using the appli...

Page 5: ...onsible for the safe use of the appliance cleaning and maintenance Improper use can lead to personal injury and damage to property 2 1 Use as intended The appliance is solely intended for preparing fo...

Page 6: ...ause serious burns X X Do not touch hot appliances X X Pay attention to the residual heat indicator DANGER Risk of electric shock or injury from damaged surfaces The underlying electronics can be expo...

Page 7: ...switch the cooktop extractor to a low power level for about 20 minutes or activate the automatic after run function WARNING Risk of burning and fire from hot objects The appliance and its exposed par...

Page 8: ...aning Steam can cause a short circuit on live parts and thus lead to property damage X X Please follow all instructions in the Cleaning and Maintenance chapter 2 4 2 Safety instructions cooktop operat...

Page 9: ...and spare parts i i The appliance must only be repaired and serviced by trained specialists who are familiar with and comply with the standard national regulations and supplementary regulations of the...

Page 10: ...the sound power level established in EN 60704 2 13 PKA3ELDEN 005 N www bora com Energy labelling PKA3 PKA3AB Product information according to delegated regulation EU no 65 2014 and regulation EU no 66...

Page 11: ...cooktop extractor All Black flexible system with separate control unit PKAS3 BORA Pro cooktop extractor system with integrated fan compact system with integrated control unit and integrated fan PKAS3A...

Page 12: ...zone 2 Control knob for left cooktop rear cooking zone 3 Control knob for cooktop extractor 4 Control knob for right cooktop front cooking zone 5 Control knob for right cooktop rear cooking zone 4 3 C...

Page 13: ...extended control options This has a Home In and a Home Out contact see the Installation chapter O O The Home In contact can be used for the signal input from external switch devices e g window contac...

Page 14: ...functions respectively are shown directly on the cooktop Control knob display Indicator Meaning 0 Cooktop is switched off 1 9 Power levels p Power setting 80 250 Temperature indicator on Tepan stainle...

Page 15: ...PKCH3 1 2 200 235 120 Fig 4 13 Layout of cooktop PKCH3 and cooking zone dimensions 1 1 ring Hyper front cooking zone 2 2 ringrear cooking zone Cooktop PKIW3 1 540 Fig 4 10 Layout of cooktop PKIW3 and...

Page 16: ...ktop PKIW3 and is available as an accessory X X Perform a magnet test if necessary If a magnet sticks to the base of the utensils they are normally induction compatible X X Pay attention to the cookwa...

Page 17: ...creases or disappears when the power level is decreased O O Crackling or whistling may occur due to cookware bases being made of different materials e g sandwich base O O Clicking sounds may occur dur...

Page 18: ...s veal poultry 180 190 Browning breaded or battered fish pancakes sausages pork lamb 190 200 Browning potato fritters prawns corn on the cob and escalopes 200 210 Fast browning beef fish meatballs 220...

Page 19: ...empty O O oil or fat is heated on high power O O a hot cooking zone is switched on again after a power cut Whilst the overheating protection is active one of the following steps is taken O O the activ...

Page 20: ...unction 3 3 3 3 3 3 3 3 3 Additional cooktop extractor functions Extractor power setting 3 3 Automatic extractor function 3 3 Automatic after run 3 3 Filter service display 3 3 Additional cooktop func...

Page 21: ...power level 0 O O Any active additional functions will be deactivated and the appliance will be switched off X X Observe all safety and warning information during operation see the Safety chapter 6 1...

Page 22: ...sponding function menu i i The cooktop extractor function menu contains both system functions and cooktop extractor functions i i If all connected appliances are switched off power level 0 the whole s...

Page 23: ...is a total of 5 additional functions to choose from Menu item Function System function Cooktop extractor function 1 A Automatic extractor function 3 2t Short time timer egg timer 3 3CL Childproofing f...

Page 24: ...r X X Open the cooktop extractor function menu X X Enter the following settings 1 2 3 Fig 6 10 Activating the short time timer egg timer O O The timer symbol flashes O O The time value 000 appears in...

Page 25: ...to start a cooking session 1 2 Fig 6 17 Closing the cover flap to start a cooking session X X Touch the cooktop extractor control knob O O The cover flap closes without grease filter and C is display...

Page 26: ...king zone with the right hand knob 1 2 Fig 6 22 Cooking zone indicator 1 active front cooking zone 2 active rear cooking zone Displaying the remaining filter service life X X Open the cooktop extracto...

Page 27: ...ckwise to power setting P 240 250 C on the Tepan stainless steel grill i i After 10 minutes the power setting is automatically switched back to power level 9 230 C on the Tepan stainless steel grill D...

Page 28: ...ing function two cooking zones can be combined to form one large cooking zone The power for the combined zones is then adjusted using any control knob Power adjustment takes place simultaneously both...

Page 29: ...r if there is no cookware present The cooking zone does not work if O O it is switched on without cookware or with unsuitable cookware O O the base diameter of the cookware is too small O O the cookwa...

Page 30: ...able heat retention function not on PKT3 The 3 heat retention levels enable cooked foods to be kept warm at a constant temperature O O The maximum duration of the heat retention function is limited to...

Page 31: ...b ring to power level 0 O O An acoustic signal sounds and the cooking zone is switched off Time lapsed O O The cooking zone switches off automatically O O An acoustic signal is heard O O 000 and the t...

Page 32: ...e displayed 6 6 4 Automatic heat up function not on PKT3 When the automatic heat up function is activated the cooking zone works at full power for a certain time and is then automatically reset to the...

Page 33: ...and both cooking zone indicators flash during the warm up phase O O As soon as the cleaning temperature is reached the cooking zone indicators are permanently lit and it is possible to start cleaning...

Page 34: ...on mode ULB1 200 h 2 Recirculation mode ULB3X 600 h Factory setting 3 Recirculation mode ULBF 300 h Tab 7 2 Exhaust air or recirculation mode and filter unit selection i i In recirculation mode the co...

Page 35: ...ated by 180 2 Not connected Tab 7 11 Set up of the right cooktop Menu item C4 operation with or without a wall sleeve only in exhaust air mode Prerequisite The exhaust air mode setting was selected in...

Page 36: ...ata export by touching the display Menu item Cd software version indicator The software currently used for all connected appliances is shown O O left cooktop O O cooktop extractor O O right cooktop It...

Page 37: ...When conducting scheduled cleaning and maintenance ensure that the cooktop and cooktop extractor are fully switched off and cooled so as to prevent injury see the Operation chapter O O Regular cleani...

Page 38: ...the maintenance tray 1 X X Lift the maintenance tray 1 out of the cooktop extractor Installing the maintenance tray Fig 8 5 Installing the maintenance tray Fitting the cover flap grease filter and fi...

Page 39: ...may damage them i i Do not use stainless steel care products on the stainless steel surfaces or the stainless steel grill surface X X Slide the maintenance tray into the cooktop extractor X X Turn the...

Page 40: ...h to dry off the surfaces that have been cleaned with water Normal soiling X X Ensure that the cleaning function is activated for both grilling zones see the Operation chapter X X Wait until the grill...

Page 41: ...rol knob display E383 The Home In contact is interrupted In exhaust air mode open the window for example Control knob display F The activated charcoal filter service life has come to an end Replace th...

Page 42: ...zone has been in operation too long Put the cooking zone back into operation see the Operation chapter The overheating protection has tripped see the Appliance description chapter The power setting is...

Page 43: ...not covered by the BORA manufacturer s warranty are O O BORA products that were not sold by authorised BORA dealers or from BORA trained salespeople O O Damage caused by non adherence to the operating...

Page 44: ...ay PKA1FW O O BORA Power supply cable Type I UNLI AUS O O BORA Power supply cable Type J UNLJ CH O O BORA Power supply cable Type G UNLG GB IE O O BORA window contact switch UFKS Special accessory for...

Page 45: ...EN 45 Notes www bora com 11 Notes...

Page 46: ...EN 46 Notes www bora com...

Page 47: ...EN 47 Notes www bora com...

Page 48: ...s eventuality An updated version can be requested from the BORA Service Team Subject to printing errors and mistakes BORA Vertriebs GmbH Co KG All rights reserved AU NZ BORA APAC Pty Ltd 100 Victoria...

Reviews: